CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
4000 Watt 24V/48V Pure Sine Wave Inverter Charger
 
Close
Shopping Categories
Search

4000 Watt 24V/48V Pure Sine Wave Inverter Charger


$1148.65
High efficiency pure sine wave inverter / charger outputs 4000W continuous power and 12000 surge power, low frequency type, o
SKU: CHN-PI-LW4000
Free Shipping Worldwide
Delivery date: 6-12 days

4000 Watt off grid inverter battery charger delivers reliable pure sine wave power from 24V/48V DC battery source, low frequency type with transformer, UPS function. The combined inverter / charger is ideal for powering refrigerators, air conditioners, TVs, fans, computers, audio/video components or other equipment, appliances and electronics. It is widely applied in wind generator, solar power system, house, vehicle, ship, navigation, mobile electricity work and telecommunications device, launch station and any places where the city power is needed.

Features

  • 4000 Watt continuous output power
  • Peak power is 3 times of rating power
  • Pure sine wave output, available for sensitive loads such as air conditioner, motor door, etc.
  • Fast and powerful inverter charger, 3-step progressive charging, 7 battery type selector
  • High power factor
  • Automatically transfer between battery and line mode
  • Microprocessor control guarantees the high reliability
  • Optional remote control function
  • Multi safety protections against over load, over temperature, over charging, and low battery
  • LCD digital display shows voltage, load and battery info in real time
  • Apply for split phase system, 2 live lines 1 neutral line, and voltage is 120V/240V

4000W Inverter/Charger Specification

ModelLW4000
Power4000 Watt
AC InputPhaseSingle Phase
WaveformPure Sine Wave
Voltage*110V/120V AC or 220V/230V/240V AC
Acceptable Voltage95-126V AC or 194-253V AC±4%
Low Line Disconnect85V AC±4% or 184V AC±4%
Low Line Re-connect95V AC±4% or 194V AC±4%
High Line Disconnect136V AC±4% or 263V AC±4%
High Line Re-connect126V AC±4% or 253V AC±4%
Frequency50Hz: 41-54Hz or 60Hz: 51-64Hz (Auto detection)
AC OutputPhase & WaveformSingle Phase & Pure Sine Wave (bypass mode sync to input)
Voltage*110V/120V AC or 220V/230V/240V AC
120V/240V AC split phase output Also Available: L1+L2=240V, L1+N=120V, L2+N=120V
Voltage Regulation±10%rms (bypass mode sync to input)
Frequency50Hz±0.3Hz or 60Hz±0.3Hz (bypass mode sync to input)
Peak Power3 times of rating power (12000W)
Short Circuit ProtectionYes, shutdown after 10ms
Power Factor0.9-1.0
OutletWiring terminal block
DC InputBattery Voltage*24V DC48V DC
Minimum Start Voltage20V DC40V DC
Low Battery Alarm21±0.6V DC42±1.2V DC
Low DC Input Shut-down20±0.6V DC40±1.2V DC
High DC Voltage Alarm & Fault32±0.6V DC64±1.2V DC
High DC Input Recovery31±0.6V DC62±1.2V DC
Max Charger Current20A/35A/50A/75A/90A (According to the inverter model)
EfficiencyLine Mode>96%
Battery Mode>85%
GeneralPower SaverLoad ≤ 25W (Enabled on "P/S auto" setting of Remote control)
Audible AlarmSounding when the heat sink's temperature is over 105℃ and shutdown after 30 seconds.
Over Load Protection110%<load<150%, beeps 0.5s every 1s, and Fault after 60s.
Load>150%, beeps 0.5s every 1s, and Fault after 20s.
ProtectionsLow battery, over charging, over temperature, over load
Remote Control*Wired remote control (5m) for power on/off
IndicatorsLCD display
Operating Environment0-40℃, 0-90%℃ RH (non-condensing)
Protection GradeIP20
Audible Noise<60dB
Net Weight35.5kg
Dimension (LxWxH)660×225×200mm

Note:
* It can be selected in the drop-down list.

Inverter/Charger Working Principle & Applications

power inverter charger working principle and applications

Inverter Split-Phase Output Terminal Description

Inverter Charger Split-Phase Output Terminal Connection

Tips: Daily Maintenance of Power Inverters

1. Check whether the load is within the rated power, the voltage range and current of the power inverter.

2. Maintain your inverters properly and regularly: use wet cloth to wipe out the external dust and dirt of the inverter; tighten the screw of the DC input terminal; use high-pressure air gun to clean up the internal dust and foreign matter.

3. Inverter must be turned off when cleaning and maintenance is carried out.

4. In the process of maintaining inverters, it is best to do the following:

  • First, periodically check whether the line part is intact. If there is something abnormal, it is necessary to timely replace.
  • Secondly, in the process of using the inverters, it is necessary to stop and check immediately if there is a problem. Only after the problem is solved, can the inverters continue to be used.
  • Thirdly, in the process of maintenance, the failure of unknown cause should be recorded in advance, and then ask the manufacturer to deal with it.
  • Fourth, when cleaning inverters, it is necessary to use soft cloth for scrubbing, not to use too much friction scrubbing tools.
  • Fifth, periodically check whether its heat sink and seal are blocked or not. If so, dust should be disposed of in time.