10kVA 120V/220V UPS Backup Uninterruptible Power Supply


$3565.87
Uninterruptible Power Supply, 10kVA/8kW, line interactive UPS, provides a reliable battery backup for critical devices like P
SKU: CHN-UPS-10K
Free Shipping Worldwide
Delivery date: 6-12 days

Applications

10kVA/8000 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computer, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copymachine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment etc.

10kVA/8000W UPS Specification

BasicModelCHN-BE-10K
Rated Capacity8000W/10kVA
PhaseSingle Phase (L, N, G)
* NOT
support the split phase (L1, L2 + G) like USA standard.
UPS TypeLine Interactive
Weight80kg
Size540*270*590mm
InputInput Voltage Range172-275V AC/ 85-135V AC
Nominal Input Voltage220V/230V/240V/110V/120V AC
Input Frequency45-65Hz
OutputNorminal Output Voltage220V/120V AC
Output Voltage Range (Normal Mode)220V/120V AC±10%
Output Voltage Range (Battery Mode)220V/120V AC±10% (Modified Sine Wave)
Output Frequency (Normal Mode)Synchronized (Sine Wave)
Output Frequency (Battery Mode)50/60Hz±0.2%
Wave FormModified Sine Wave
Power Factor0.9
Output SocketUniversal socket
Efficiency>90%
Transfer Time6-8ms
Batteries & RuntimeBattery TypeMaintenance-free lead-acid battery
Battery Modules (NOT Included)12V*12Ah*8pcs/96V
(Battery size: 150*90*60mm)
Backup Time (full/half load)5 minutes backup time; for long backup mode, it depends on outside batteries
Charge Time<12 hours (90%)
Display StatusLCD (NORMAL, FAULT, BATTERY, CHARGE, OVERLOAD)
ProtectionOverload ProtectionAutomatic shut down when overload is within 110~130%
Shut down after 300ms when above 130%
OthersPeak Ratio for Load3:1 (Max.)
Distortion Rate (full load) Linear Load<3%
Distortion Rate (full load) Non-linear Load<6%
Communication SoftwareNETCCA POWER
Operating EnvironmentWorking Temperature0°C~40°C
Relative Humidity20~90% Non-condensing

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. If you need other output voltage range, please contact us.

Tips: Troubshooting UPS - the battery voltage is low but the battery cannot be charged for more than 10 hours.

Judging from the phenomenon, it is the fault of battery and charging circuit, which can be inspected according to the following procedures.

  1. Check whether the input and output voltage of the UPS charging circuit is normal. 
  2. If the charging circuit is in normal input and abnormal output, disconnect the UPS battery to test again. If it is still abnormal, it is the fault of the charging circuit.
  3. If the charging circuit has normal input and output after the battery is disconnected, it indicates that the UPS battery has been damaged because of the long term charging, long time placement, due life period.