Tension and compression load cells have capacity range from 1kg, 2kg, 3kg, 10kg to 50kg. Load cell capacity can be customized according to customer requirements.
After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.
Specification:
Model | CHN-LCS-DYLY-106 |
Weight | 0.06kg |
Capacity range * | 0kg~50kg |
Accuracy | 0.03%F.S (linearity + hysteresis + repeatability) |
Sensitivity | 2.0±0.05mV/V |
Creep | ±0.03%F.S/30min |
Zero output | ±1%F.S |
Temperature effect on zero | ±0.03%F.S/10℃ |
Temperature effect on output | ±0.03%F.S/10℃ |
Operating temperature | -20℃~+80℃ |
Input impedance | 350±20Ω |
Output impedance | 350±5Ω |
Insulation resistance | ≥5000MΩ |
Safety overload | 150%F.S |
Bridge voltage (excitation voltage) | DC 5-15V, suggest DC 10V |
Material | Alloy steel |
Protection class | IP67 |
Cable length | 2m |
Wiring | EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White |
Dimension (unit: mm):

Tips: How to judge lead wire of load cell?
The output resistance of the load cell is generally 350Ω, 480Ω, 700Ω, 1000Ω. The input terminal will be conducted with temperature and sensitivity compensations. Therefore, the resistance of the input terminal will be 20~100Ω higher than that of the output terminal. Therefore, if the multimeter is used to measure the resistance value, the input and output terminals can be judged. Normally, the colors of the input and output terminals are red, black, green and white. They are respectively marked as EXC+, EXC-, SIG+ and SIG-.
S type load cell can bear both tension and pressure, with good stability, good output symmetry, high accuracy, low temperature drift, compact structure and complete specifications. Micro load cell is suited to use in restricted spaces.