Miniature circuit breaker is characterized by compact structure, reliable performance, good interrupt capacity and small size, widely used as short circuit and overload protector in industrial, commercial and residential areas.
Circuit Breaker Information
- Rated Current: 63 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of pole: 2 poles
- 6 kA short circuit breaking capacity
- Compliance with IEC standard
- C curve trip characteristic
- Breakers mounting on standard 35 mm DIN rail
Technical Data
Model | CHN-NB8-632PC63 |
Electrical Parameters | Height | 86 mm |
Width | 18 mm per pole |
Mounting | DIN Rail |
Rated Current (In) | 63A |
Number of poles | 2P |
Rated Voltage (Ue) | 230/400V |
Rated Insulation Voltage (Ui) | 500V |
Dielectric Test Voltage | 2000V |
Reted Frequency | 50Hz |
Short Circuit Interrupting Capacity | 6KA |
Trip Characteristic | C Curve (5-10In) |
Rated Short-Circuit Breaking Capacity | 6000A |
Operating Short-Circuit Breaking Capacity | 6000A |
Mechanical Parameters | Electrical Life | 10000 times |
Mechanical Life | 20000 times |
Flame Retardant Grade | V0 |
Protection Degree | Direct installation: IP20B Installed in the distribution box: IP40B |
Calibration Temperature | 30℃ |
Operating Temperature | -35℃~+70℃ |
Storage Temperature | -35℃~+85℃ |
Tightening Torque | 2 N.m |
Max. Tolerable Torque | 2.5 N.m |
Terminal Size Acceptability–Min/Max | 1 mm2 / 25mm2 |
Wire Insertion Depth | 13mm |
Circuit Breaker Dimensions (Unit: mm)

Tips: Types of the low-voltage circuit breakers
The low-voltage circuit breaker is also named as the automatic air switch. It is mainly used as the power switch in the low-voltage distributing line or switch cabinet (box) not operated frequently and can be used to control the motor not started frequently. When there is any serious overcurrent, overload, short circuit, phase loss, electricity leakage and other faults, it can cut off the power supply automatically and play a role of protection.
- Air circuit breaker in frame type(conventional)-ACB
All components of ACB are installed in one insulated metal frame. It is normally the open-type. It can be equipped with several accessories, so the exchange of contact terminal and component are rather convenient. It is mostly used for the main switch of the power terminal. - Molded case circuit breaker-MCCB
MCCB can cut off the current automatically when the current exceeds the current tripping setting. MCCB usually includes the thermomagnetic tripping unit. However, the large-size MCCB will be equipped with the solid tripping sensor. It is appropriate for being the protective switch of the branch. - Miniature circuit breaker-MCB
MCB is a kind of terminal protective equipment which is mostly extensive used in the power distribution unit of the architecture electric terminal. It is used for the single-phase, three-phase short circuit, overload and over pressure protections below 125A, including the single pole 1P, dipolar 2P, tripolar 3P and quadrupole 4P.
Small-size circuit breaker features 63 amp current rating, 2 poles, 6 kA interrupt capacity, DIN rail mounting and C curve trip characteristic. As IEC listed, MCB is suitable for protecting the electrical equipment from over load and short circuit.