Miniature circuit breaker is generally used as supplementary protector for short circuit and overload protection in residential, commercial and industrial areas in accordance with IEC standards.
Circuit Breaker Information
- Rated Current: 25 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of pole: 2 poles
- 6 kA short circuit breaking capacity
- Compliance with IEC standard
- C curve trip characteristic for short circuit and overload protection for different applications
Technical Data
Model | CHN-NB8-632PC25 |
Electrical Parameters | Height | 86 mm |
Width | 18 mm per pole |
Mounting | DIN Rail |
Rated Current (In) | 25A |
Number of poles | 2P |
Rated Voltage (Ue) | 230/400V |
Rated Insulation Voltage (Ui) | 500V |
Dielectric Test Voltage | 2000V |
Reted Frequency | 50Hz |
Short Circuit Interrupting Capacity | 6KA |
Trip Characteristic | C Curve (5-10In) |
Rated Short-Circuit Breaking Capacity | 6000A |
Operating Short-Circuit Breaking Capacity | 6000A |
Mechanical Parameters | Electrical Life | 10000 times |
Mechanical Life | 20000 times |
Flame Retardant Grade | V0 |
Protection Degree | Direct installation: IP20B Installed in the distribution box: IP40B |
Calibration Temperature | 30℃ |
Operating Temperature | -35℃~+70℃ |
Storage Temperature | -35℃~+85℃ |
Tightening Torque | 2 N.m |
Max. Tolerable Torque | 2.5 N.m |
Terminal Size Acceptability–Min/Max | 1 mm2 / 25mm2 |
Wire Insertion Depth | 13mm |
Circuit Breaker Dimensions (Unit: mm)

Tips: Difference between molded case circuit breaker and miniature circuit breaker
1. Current grade
The current grade of the molded case circuit breaker can reach as high as 2000A while the maximum current of the miniature circuit breaker is within 125A. Because of the volume difference of the two types, in detailed application, the effective area of the molded case circuit breaker is also bigger than that of the miniature circuit breaker. Meanwhile, the connected wire is also relatively thick, which can reach 35 square. However, the miniature circuit breaker is only suitable to be connected with the wire below 10 square.
2. Installing means
The molded case circuit breaker is mainly installed by screws while the miniature circuit breaker is mainly installed through guide rail.
3. Operation flexibility
The overcurrent and short-circuit protective equipment of the molded case circuit breaker are independent respectively. In the operation process, the operate value of the overcurrent protection still can be regulated flexibly. The overcurrent protection and the short-circuit protection of the miniature circuit breaker is the unified equipment. It has a certain deficiency in the regulating flexibility. However, when it is required to improve the safety of the equipment, because the movement of the miniature circuit breaker has a high sensitivity, quick breaking action, it is beneficial for protecting the wire and apparatus.
25 amp 2-pole mini circuit breaker, with 6 kA short circuit breaking capacity at 230/400V AC, C curve availble. Compliance with IEC standards, meet general purpose needs of protecting branch circuit, easy mounting in DIN rail, high reliability and safe in use.