Close
Shopping Categories
Search

13 amp 4 pole Miniature Circuit Breaker


$40.31
13 amp, 4 pole miniature circuit breaker with 10kA short circuit interrupting capacity, standard 35 mm DIN rail mounting, 18
SKU: CHN-MCB-4P13
Free Shipping Worldwide
Delivery date: 6-12 days

Circuit Breaker Information

  • Model: ATOCLXB4-13
  • Rated Current: 13A
  • Rated Voltage: 230/400V AC, 50Hz/ 60Hz
  • Number of poles: 4 pole
  • 10 kA short circuit breaking capacity
  • Accordance with IEC standard
  • Possibility for locking the toggle in ON or OFF position
  • Three different trip characteristics, including B, C and D curves, give you the ability to configure the exact protection scheme you required

Miniature circuit breaker is ideal for the protection of circuits in industrial, commercial, and residential sectors, and ensures the following functions: Protection against short-circuit and overload currents, isolation, protection of persons against indirect contact.

Technical Data

Standard CertificationsIECUL1077
Electrical ParametersHeight86 mm
Width18 mm per pole
MountingDIN Rail
Rated Current (In)1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A (Available)
Number of poles1P, 2P, 3P, 4P (Available)
Rated Voltage (Ue) (Optional)240/415V or 230/400V277/480V
Rated Insulation Voltage (Ui)500V
Reted Frequency50Hz/60Hz
Short Circuit Interrupting Capacity (Optional)6/10KA5KA
Trip Characteristic (Optional)B Curve (3-5In)B Curve (4In)
C Curve (5-10In)C Curve (7In)
D Curve (10-20In)D Curve (14In)
Mechanical ParametersElectrical Life8000 times
Mechnical Life10000 times
Protection DegreeIP20
Calibration Temperature30
Operating Temperature-5℃~+40℃
Storage Temperature-25℃~+70℃
Tightening Torque22 Ib-in (2 Nm)
Terminal Size Acceptability–Min/Max2.5 mm2(12 AWG) / 25mm2(3 AWG)

Circuit Breaker Dimension (Unit: mm)

circuit breaker dimensionTips: What is a moulded case circuit breaker?
The moulded case circuit breaker is also named as the equipment-type circuit breaker. The moulded case refers that the plastic insulator is used as the enclosure of the equipment. All components are sealed in the plastic enclosure, so as to isolate the conductors and the grounding metal parts. The moulded case circuit breaker can cut off the current automatically when the current exceeds the tripping setting. Because the structure is very compact, the moulded case circuit breaker is basically unable to be repaired.
The moulded case circuit breaker equips the contact, arc extinguish chamber, release and operating mechanism and so on in one plastic enclosure. Normally, maintenance is not considered. It is suitable to be used as the protective switch of the branch. The overcurrent release has thermomagnetic type and electronic type. Usually, the thermomagnetic moulded case circuit breaker is the non-selected circuit breaker, which only has the overload long time delay protection and short-circuit instant protection. However, the electronic moulded case circuit breaker has four protective functions, which are respectively: Overload long time delay, short-circuit short delay, short-circuit instant and grounding fault. Some new promoted electronic moulded case circuit breakers still have the function of regional selective interlock. Most of the moulded case circuit breakers are in manual operation while some are also equipped with the motor operation mechanisms.