2 amp 4 pole Miniature Circuit Breaker


$93.29
Compact miniature circuit breaker, 2 amp, 4 pole, with 6 kA short circuit breaking capacity at 230/400V AC, and C curve trip
SKU: CHN-MCB-4P02
Free Shipping Worldwide
Delivery date: 6-12 days

Circuit Breaker Information

  • Rated Current: 2 amp
  • Rated Voltage: 230/400V AC, 50Hz
  • Number of poles: 4 pole
  • 6 kA short circuit interrupting capacity
  • 35mm DIN rail mounted
  • It can be manually switched ON and OFF as similar to normal switch if necessary
  • Thermal-magnetic overcurrent protection, three levels of short circuit protection

Technical Data

ModelCHN-NB8-634PC02
Electrical ParametersHeight86 mm
Width18 mm per pole
MountingDIN Rail
Rated Current (In)2A
Number of poles4P
Rated Voltage (Ue)230/400V
Rated Insulation Voltage (Ui)500V
Dielectric Test Voltage2000V
Reted Frequency50Hz
Short Circuit Interrupting Capacity6KA
Trip CharacteristicC Curve (5-10In)
Rated Short-Circuit Breaking Capacity6000A
Operating Short-Circuit Breaking Capacity6000A
Mechanical ParametersElectrical Life10000 times
Mechanical Life20000 times
Flame Retardant GradeV0
Protection DegreeDirect installation: IP20B
Installed in the distribution box: IP40B
Calibration Temperature30℃
Operating Temperature-35℃~+70℃
Storage Temperature-35℃~+85℃
Tightening Torque2 N.m
Max. Tolerable Torque2.5 N.m
Terminal Size Acceptability–Min/Max1 mm2 / 25mm2
Wire Insertion Depth13mm

Circuit Breaker Dimension (Unit: mm)

2 amp 4 pole Miniature Circuit Breaker Dimensions

Tips: Basic requirements for the operating mechanism of a circuit breaker
Because the effective and reliable movement of a circuit breaker depends on the performance and quality of the operating mechanism in a larger degree, according to the different circuit breakers, the equipped operating mechanism must satisfy the required property and reliability. It mainly includes the following points:

  1. Possess the closing maintaining function. When the operating command lasts a short period and the operating function has short coordination, there must be a closing maintaining mechanism, so as to ensure that the circuit breaker is still in the closing position after the closing command and operating function disappear.
  2. Possess a relatively short separating time. The closing time should be irrelevant to the action speed of the operator and the time length of command transmitting. At least, the separating speed must be required to not likely to result in the arc reignition, so as to shorten the separating time as much as possible and reduce the existing time of the short-circuit fault, thus improving the stability of the power system and minimizing the fault scope as much as possible.
  3. Possess an anti-pumping equipment. In order to avoid the continuous multiple phenomenon of the circuit breaker after closing, it is necessary to use mechanical or electric method, so that the circuit breaker can not be divided and closed after the break, so as to reduce unnecessary actions.
  4. Possess an interlock equipment. With the interlock equipment in the operating mechanism, the reliability of the circuit breaker can be guaranteed. As a result, when the circuit breaker is in a kind of status, being affected by the wrong action of the operating mechanism, the general operating mechanism must possess separating position interlock, low-pressure and high-pressure interlock, position interlock in the spring mechanism and so on.