1 amp 2 pole Miniature Circuit Breaker


$68.99
Low price 1 amp 2 pole miniature circuit breaker meets IEC standard to provide the supplementary protection for the electrica
SKU: CHN-MCB-2P01
Free Shipping Worldwide
Delivery date: 6-12 days

Mini circuit breaker (MCB) is an electrical Switch which automatically switches off the electrical circuit during an abnormal condition of the network means in overload condition as well as faulty condition.

Circuit Breaker Information

  • Rated Current: 1 amp
  • Rated Voltage: 230/400V
  • Number of pole: 2 poles
  • 6 kA short circuit breaking capacity
  • Compliance with IEC standard
  • C curve trip characteristic gives you the ability to configure the exact protection scheme you required.

Technical Data

ModelCHN-NB8-632PC01
Electrical ParametersHeight86 mm
Width18 mm per pole
MountingDIN Rail
Rated Current (In)1A
Number of poles2P
Rated Voltage (Ue)230/400V
Rated Insulation Voltage (Ui)500V
Dielectric Test Voltage2000V
Reted Frequency50Hz
Short Circuit Interrupting Capacity6KA
Trip CharacteristicC Curve (5-10In)
Rated Short-Circuit Breaking Capacity6000A
Operating Short-Circuit Breaking Capacity6000A
Mechanical ParametersElectrical Life10000 times
Mechanical Life20000 times
Flame Retardant GradeV0
Protection DegreeDirect installation: IP20B
Installed in the distribution box: IP40B
Calibration Temperature30℃
Operating Temperature-35℃~+70℃
Storage Temperature-35℃~+85℃
Tightening Torque2 N.m
Max. Tolerable Torque2.5 N.m
Terminal Size Acceptability–Min/Max1 mm2 / 25mm2
Wire Insertion Depth13mm

Circuit Breaker Dimensions (Unit: mm)

1 amp 2 pole Miniature Circuit Breaker Dimensions

Tips: Short circuit protection of miniature circuit breaker

The short-circuit protection function of the miniature circuit breaker is realized by the instantaneous release. According to the analysis of F=IN (the suction force is proportional to the product of the current and the number of turns), although the instantaneous release is connected in series in the circuit, when the circuit is working normally, because the small number of turns, the suction force generated by the normal working current is not enough to overcome the reaction force of the spring, the line can work normally. When the line is short-circuited or severely overloaded, a very high current flows through the induction coil to generate a strong magnetic field. Since the current generated is different from the normal working current by several times or even tens of times or more, the number of coil turns has not changed. , But the current has increased several times or even dozens of times, so the suction force has also increased several times or even dozens of times. Pushing the lever makes the circuit breaker trip quickly. Due to the large current, the tripping time of the circuit breaker is generally within 0.1s. Moreover, as long as the reaction spring is selected reasonably, it can meet the setting requirements of B curve, C curve and D curve instantaneous releases.