Discounted 2 hp VFD, customized non-enclosure desgin, single phase input and output, 7.5 amps, brand new direct sale by manufacturer.
Specification:
Basics | Model | GK3300-2S0015 |
Capacity | 2 hp (1.5 kW) |
Shipping weight | 887 g |
Dimension (L*W*H) | 150*98*114 mm |
I/O Feature | Rated current | 7.5 A |
Input voltage | 1 phase 220~240V AC |
Input frequency | 50Hz/ 60Hz |
Output voltage | 1 Phase/3 phase AC 0~input voltage |
Output frequency | 0.00~400.00Hz |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds |
Control Feature | Control mode | V/F control; Sensorless vector control; |
Communication | RS485 |
Speed regulation | 1:100 |
Start torque | 150% of rating torque at 1 Hz |
Speed control accuracy | ≤±0.5% of rating synchronous speed |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% |
Interior PID controller | Be convenient to make closed-loop system |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip |
Environment | Enclosure rating | IP 20 |
Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% |
Humidity | 5%-95%, without condensation |
Altitude | ≤1000m; VFD will be derated if above 1000m |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) |
Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Whether the VFD is suitable for your application.
The main function of the variable frequency drive (VFD) is to change the speed of the AC motor. VFD also provides non-emergency start & stop control, acceleration, deceleration and overload protection. In addition, the frequency inverter can reduce the motor startup inrush current by gradually accelerating the motor. ATO VFD is suitable for machines such as conveyors, fans and pumps which benefit from reduced and controlled motor operating speeds.
High quality 2 hp (1.5 kW) single phase VFD without enclosure, 220-240v 1-phase input to 1ph & 3ph output, built-in braking unit, V/F control, sensorless vector control, driving single and three phase AC motors.