Close
Shopping Categories
Search

1/4 hp Non-Enclosure VFD, 1ph Input, 1ph/3ph Output


$119.23
Customized no shell single phase VFD for sale, 1/4 hp (200 W) capacity variable speed drive, convert single phase 208~240v to
SKU: GK3300-2S0002
Free Shipping Worldwide
Delivery date: 6-12 days

1/4 hp single phase VFD without enclosure, 0.2 kW, 220V single phase to 1-phase or 3phase 220 volt output variable frequency drive, sale by manufacturer directly.

Specification:

BasicsModelGK3300-2S0002
Capacity1/4 hp (0.2 kW)
Shipping weight665 g
Dimension (L*W*H)151*104*73 mm
I/O FeatureRated current1.6 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage1 Phase/3 phase AC 0~input voltage
Output frequency0.00~400.00Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Tips: The application usually determines the control mode of the VFD
Volts per Hertz (V/F)
V/F controls the ratio between voltage and frequency to change the motor flux, thereby providing the motor with operating torque. The V/F drive works well for most applications such as fans and water pumps.
Sensorless vector
Sensorless vector VFDs are known for their precise speed control over a wide speed range without encoder feedback, because they work well in open loop. The closed loop VFD uses encoder feedback to perform precise speed control by monitoring the actual motor speed and slip information. Sensorless vector and closed-loop VFD have excellent speed regulation, providing accurate speed control for paper mills, printing presses and other conversion applications.