Specification:
Basics | Model | GK3300-2S0002 |
Capacity | 1/4 hp (0.2 kW) |
Shipping weight | 665 g |
Dimension (L*W*H) | 151*104*73 mm |
I/O Feature | Rated current | 1.6 A |
Input voltage | 1 phase 220~240V AC |
Input frequency | 50Hz/ 60Hz |
Output voltage | 1 Phase/3 phase AC 0~input voltage |
Output frequency | 0.00~400.00Hz |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds |
Control Feature | Control mode | V/F control; Sensorless vector control; |
Communication | RS485 |
Speed regulation | 1:100 |
Start torque | 150% of rating torque at 1 Hz |
Speed control accuracy | ≤±0.5% of rating synchronous speed |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% |
Interior PID controller | Be convenient to make closed-loop system |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip |
Environment | Enclosure rating | IP 20 |
Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% |
Humidity | 5%-95%, without condensation |
Altitude | ≤1000m; VFD will be derated if above 1000m |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) |
Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: The application usually determines the control mode of the VFD
Volts per Hertz (V/F)
V/F controls the ratio between voltage and frequency to change the motor flux, thereby providing the motor with operating torque. The V/F drive works well for most applications such as fans and water pumps.
Sensorless vector
Sensorless vector VFDs are known for their precise speed control over a wide speed range without encoder feedback, because they work well in open loop. The closed loop VFD uses encoder feedback to perform precise speed control by monitoring the actual motor speed and slip information. Sensorless vector and closed-loop VFD have excellent speed regulation, providing accurate speed control for paper mills, printing presses and other conversion applications.