Magnetostrictive level sensor with measuring range 50mm is used for the liquid level preset and feedback, such as the liquid level of oil tank. Magnetostrictive sensors also can be used in most industrial automation systems.
Specification:
Basics | Model | CHN-MSL-0050 |
Measuring range | 0~50 mm |
Shipping weight | 1 kg |
Length | 249.3 mm |
Diameter | 50 mm |
Technical parameters | Linearity | ≤0.03%FS |
Repeatability | ≤0.003%FS |
Resolution ratio | ≤0.001%FS |
Hysteresis | ≤0.001%FS |
Working Voltage | 24V /12V DC |
Working current | Voltage /digital output type≤16mA; Current output type≤35mA |
Output method | 0~5V / 0~10V / 4~20mA / 0-20mA RS485 binary digital signal / SSI gray code signal |
Product type | Normal type; Explosion-proof type; Anti-corrosion type |
Measuring rod material | 0Cr18Ni9 (304) or 316L stainless steel (secial custom-made) |
Measuring rod diameter | Ф10mm |
Electronic bin material | 1Cr18Ni9 (304) |
304 and PTFE casing outside (Anti-corrosion type, special custom-made) |
1Cr18Ni9Ti and protection cover outside (Anti-corrosion type, special custom-made) |
Connecting screw thread | M18×1.5; M20×1.5; 3/4-16UNF |
Type of lead wire | PVC shielded cable; aviation plug (not applicable to explosion-proof type) |
Measuring rod pressure | 40MPa, 70MPa (Explosion-proof type) |
Temperature | T1: 0~+ 70℃, T2: -25~+80℃, T3: -40~+120℃ |
Buffer area | Front-end of buffer 50.8mm (electronic bin), the end of the buffer 63.5mm (the buffer area can be custom-made) |
Vibration | 100g, IEC standards 68-2-715g /10-2000Hz IEC standards 68-2-6 |
Protection Class | IP67 |
Explosion-proof level | Explosion-proof type: EXd II BT5 |
Installation diagram (unit: mm):

Tips: What is the absolute position output and rated measuring range of magnetostrictive sensor
The sensor position output is relative to an absolute (fixed) reference point. The sensor no need to reset necessarily after power restoration in case of power failure. Unlike general incremental sensors (e.g.: incremental encoder and grating scale), the system should be reset after outage to continue measurement.
Rated measuring range indicates the detection area practically available for the sensor, and it is definitely marked on order number. The rated detection length is certainly shorter than the total length of the sensor due to the existence of measuring blind zone at head and terminal end.
Non contact fuel level sensor for oil tank, high precision, no temperature drift, anti-jamming performance, long life, high temperature resistance, corrosion resistance, high pressure resistant.