8kVA 240V to 120V/240V Split Phase Transformer


$3765.98
8kVA single phase to split phase transformer for 50/ 60Hz AC circuit, convert the input voltage AC 240V to the output voltage
SKU: CHN-DGS8kVA
Free Shipping Worldwide
Delivery date: 6-12 days

Single phase to split phase transformer capacity 8kVA, transform primary voltage 240V to secondary voltage 120V/240V, IP20 protection grade enclosure makes the device suitable for indoor and outdoor applications.

 8 kVA Single Phase to Split Phase Transformer Specifications

ModelCHN-DGS8kVA
PhaseSingle phase to split phase
Capacity8 kVA
Primary Voltage1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency50/60Hz
Winding MaterialAluminum/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength2000V AC/1 min
Noise≤35dB (1 meter)
Insulation GradeGrade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling MethodNatural or air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test125Hz/800V/min
Transformation Ratio<3%
Air Carrying Current<6%
Impedance VoltageAbout 6%
Total Losses10%
CertificationCE, ISO
Temperature-15℃~+45℃
Humidity≤90%RH, without condensation
Altitude<2000m, non corrosive gas and conductive dust
Enclosure Protection GradeIP20
Warranty12 months
Weight of Aluminium Wire TransformerOpen type: 80kg
Protected type: 102kg
Weight of Copper Wire TransformerOpen type: 90kg
Protected type: 124kg

8 kVA Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
8 kVA Single Phase to Split Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=290*300*350mmOpen type: a*b*c=300*310*345mm
Mouting size: D*E=150*180mm (aperture: 20*10mm)Mouting size: 190*190mm (aperture: 20*10mm)
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=380*530*560mm

Tips: Transformer overload operation

Before overload operation, check whether the transformer has serious defects (such as abnormal cooling system, serious oil leakage, partial overheating, abnormal analysis results of dissolved gas in oil, etc.) or insulation weakness. If so, it should not be overrun. Load operation. When the transformer is running under overload, the spare cooler should be put into operation immediately, and the temperature of the upper layer of the transformer, ambient temperature and time should be observed. And record the overload time and overload multiple, the overload multiple during normal overload operation.