3kVA 220V to 120V/240V Split Phase Transformer


$2156.89
3kVA single phase to split phase transformer convert AC220V to 120V/240VAC, the primary voltage can also choose 110V, 208V, 2
SKU: CHN-DGS3kVA
Free Shipping Worldwide
Delivery date: 6-12 days

Low-cost transformer has a capacity of 3kVA, single phase 220V to split phase 120V/240V, used for for 50/ 60Hz AC circuit. IP20 protection grade enclosure makes the device suitable for indoor and outdoor applications.

3 kVA Single Phase to Split Phase Transformer Specifications

ModelCHN-DGS3kVA
PhaseSingle phase to split phase
Capacity3 kVA
Primary Voltage1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency50/60Hz
Winding MaterialAluminum/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength2000V AC/1 min
Noise≤35dB (1 meter)
Insulation GradeGrade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling MethodNatural or air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test125Hz/800V/min
Transformation Ratio<3%
Air Carrying Current<6%
Impedance VoltageAbout 6%
Total Losses10%
CertificationCE, ISO
Temperature-15℃~+45℃
Humidity≤90%RH, without condensation
Altitude<2000m, non corrosive gas and conductive dust
Enclosure Protection GradeIP20
Warranty12 months
Weight of Aluminium Wire TransformerOpen type: 45kg
Protected type: 63kg
Weight of Copper Wire TransformerOpen type: 48kg
Protected type: 68kg

Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
3 kVA Split Isolation Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=240*240*260mmOpen type: a*b*c=240*230*260mm
Mouting size: D*E=180*170mm (aperture: 20*10mm)Mouting size: 180*160mm (aperture: 20*10mm)
Protected type: A*B*C=300*440*500mmProtected type: A*B*C=380*530*560mm

Tips: Working principle of rectifier transformer

The windings are composed of two independent wires of primary and secondary and share an iron core. The primary winding is connected to the AC power supply, and the alternating current flows in to generate magnetic potential. The magnetic flux flows in the closed iron core. Alternating current of the same frequency is induced in the secondary winding.

At the beginning of the transformer, the turns ratio of the secondary winding is equal to the voltage ratio. In order to obtain multiple output voltages, some transformers can have multiple secondary windings and taps.