CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
150 kVA Isolation Transformer, 3 phase, 240 Volt to 400 Volt
 
Close
Shopping Categories
Search

150 kVA Isolation Transformer, 3 phase, 240 Volt to 400 Volt


$19098.65
150 kVA isolation transformer with high quality and cheap price. 3 phase to 3 phase, (we can customize 3 phase voltage to si
SKU: CHN-T-SG150KVA
Free Shipping Worldwide
Delivery date: 6-12 days

Three phase 150 kVA isolation transformers is 50/60Hz rated, dry type air self cooling of cooling method, convert 240 Volt voltage to 120 Volt voltage. The lower operating costs, lower heat emissions make this transformer ideal for a wide range of applications.

Generally, isolation transformers with power above 150KVA will be equipped with an alarm, which is used to detect the temperature of the transformer. When the temperature of the transformer rises to 150 degrees, the alarm will be triggered. At this time, the transformer needs to be manually suspended or stopped. Wait until the transformer temperature returns to normal, then continue to use.

150 kVA Isolation Transformer Specifications

BasicsModelATOSG-150KVA
Phase3 phase
Capacity150 kVA
Weight of Aluminium Wire TransformerOpen type: 420kg
Protected type: 535kg
Weight of Copper Wire TransformerOpen type: 465kg
Protected type: 580kg
Technical ParametersPrimary Voltage240V (optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 22
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

High capacity isolation transformer details

150 kVA Isolation Transformer Installation Dimension

150kVA 800kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=820*400*800mmOpen type: a*b*c=855*400*695mm
Mouting size: d*e=500*350mmMouting size: d*e=500*350mm
Protected type: A*B*C=1050*600*1400mmProtected type: A*B*C=1050*600*1400mm

Tips: Difference between isolation transformer and voltage regulator

As we known, electricity is capable of generating a magnetic field that is also converted into electricity. The principle of single phase or three phase isolation transformer refers that a coil charged with alternating current generates an alternating magnetic field and this alternating magnetic field passes through another coil where voltage will be induced. The transformer ratio is related to the number of these two windings. In brief, under the principle of magnetic coupling, transformer is made of original edging windings and the voltage of both coil ends is directly proportional to the number of windings. Therefore, the transformer ratio is determined by the number of original edging windings.

It is obvious that transformer is not a voltage regulator, because the auxiliary edging voltage changes with the original edging voltage.

Voltage regulator follows the principle of negative feedback. For example, turn on the tap to half and install a sensor at the exit of tap to detect the amount of water. If the amount of water is too large, the tap will be triggered to turn down automatically. On the contrary, if the amount of water is too small, the amount of water will be triggered to turn up automatically till a constant water flow. The principle of voltage regulator is as follows: There is an error amplifier inverting input divider resistance sampling circuit that can detect the changes of output voltage can be compressed into an integrated chip in the regulator. When the output voltage changes, the feedback on the circuit detected with voltage changes will be provided to the private service motor by the chip and the automatic adjustment of electric brush position will be activated by the pivoted arm triggered by a private service motor in order to stabilize the output voltage, which is the simplest voltage regulator.