15 kVA Isolation Transformer, step up/step down 415V with 208V


$3203.97
3 phase high quality isolation transformer with 15 kVA power rating, better dielectric strength and insulation resistance. St
SKU: CHN-T-SG15KVA
Free Shipping Worldwide
Delivery date: 6-12 days

15kVA isolation transformer is dry type air self cooling one, Which is available in the circuit of AC 50Hz/60Hz and step up 3 phase voltage 208V to 415V, also step down 415V to 208V vertion for selection, long life span and high efficiency.

15 kVA Isolation Transformer Specifications

BasicsModelATOSG-15KVA
Phase3 phase
Capacity15 kVA
Weight of Aluminium Wire TransformerOpen type: 100kg
Protected type: 130kg
Weight of Copper Wire TransformerOpen type: 105kg
Protected type: 135kg
Technical ParametersPrimary Voltage415V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage208V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP24 or IP54 (Optional)
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:
Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

15 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*280*380mmOpen type: a*b*c=380*260*380mm
Mouting size: d*e=260*180mmMouting size: d*e=260*160mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=380*530*560mm

Tips: ATO three phase isolation transformer working principle

Three phase isolation Transformer mainly applies electromagnetic induction principle to work, the working principle details are as follows: When the primary side of the isolation transformer is applied with the alternating voltage U1 and the current flowing through the primary winding is I1, then the current will generate alternating magnetic flux in the iron core to generate electromagnetic connections between the primary winding and the secondary winding.

According to the electromagnetic induction principle, electromotive force will be induced when the alternating magnetic flux goes through these two windings. The magnitude of electromotive force is proportional to the winding turns and the maximum main flux, the voltage of more winding turns is high and the voltage of less winding turns is low. When the secondary side of the transformer opens circuit, that is to say when the transformer is no-load, the primary and secondary end voltage is proportional to the number of the primary and secondary winding turns, that is U1/U2 = N1/N2, but the primary and secondary frequency stays the same to realize the change of voltage.