8 kVA Isolation Transformer, 480V 3 phase to 240V 3 phase


$2333.08
480 Volt 3 phase to 240 Volt 3 phase isolation transformer, 8 kVA power rating, primary and secondary windings are separated
SKU: CHN-T-SG8KVA
Free Shipping Worldwide
Delivery date: 6-12 days

Three phase 8kVA isolation transformer is designed to step down/up the voltage 480V to 240V, and widely used in various power supply sites with frequency 50Hz/60Hz.

8 kVA Isolation Transformer Specifications

BasicsModelATOSG-8KVA
Phase3 phase
Capacity8 kVA
Weight of Aluminium Wire TransformerOpen type: 75kg
Protected type: 90kg
Weight of Copper Wire TransformerOpen type: 80kg
Protected type: 92kg
Technical ParametersPrimary Voltage480V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage240V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

8 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*220*380mmOpen type: a*b*c=380*220*380mm
Mouting size: d*e=260*130mmMouting size: d*e=260*130mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=380*530*560mm

Tips: ATO Step up & step down isolation transformer shell selection

The selection of the shell is also very important to the isolation transformer protection and it should be according to the requirements of protection and the using environment, so the shell forms are diversified. Conventionally, the ATO step up/down single phase and three isolation transformer shell selects IP20 mainly to protect the live parts and to prevent the cats and rats as well as some larges and 12mm diameter foreign matters into the transformer, which may cause short-circuit and other serious accidents. In addition, the outdoor transformer protective shell needs to select IP23, which not only has the above functions, but also can avoid droplets within vertical 60 degrees. However, this will have an impact on the cooling capacity of the isolation transformer, so the operation capacity needs to be paid attention to.