300 hp (220 kW) VFD, 3 Phase 240V, 415V, 460V


$9813.41
Economic 300 hp (220 kW) variable frequency drive (VFD) for energy savings, vary motor speed and make motor in soft starting
SKU: GK3000-4T2200G
Free Shipping Worldwide
Delivery date: 6-12 days

300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T2200G
Capacity300 hp (220 kW)
Shipping weight115 kg
Dimension810*640*350 mm
I/O FeatureRated current426 A
Input voltageThree phase 240V /415V /460V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltageThree phase AC 0~input voltage
Output frequency0.00~400.00Hz
Over load capacity150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Tips: Variable frequency drive development trend

  1. Low electromagnetic noise and mute
    In addition to using the high frequency carrier sine wave SPWM modulation to achieve low noise, the VFD input side plus AC reactor or active power factor correction circuit APFC, and the inverter circuit also using SOFT-PWM control technology to improve the input current waveform, reduce the harmonic wave of the grid. The VFD meets the EMC international standard in anti-interference and inhibits the higher harmonic, and to achieve clean energy conversion.
  2. Customization
    The new VFD in order to better play the unique function of frequency control technology, and as far as possible to meet the needs of field control, derived from a number of customization models such as fan water pump air-conditioning dedicated model, heavy machinery dedicated model, AC elevator dedicated model, textile machinery dedicated model and so on.
  3. Systematic
    In addition to the development of digital, intelligent and multi-functional, the VFD is also developing to the integrated and systematic direction. The purpose is to provide the best system functions for users.
  4. Network