Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
7.5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD
 
Close
Shopping Categories
Search

7.5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD


$726.89
Customizable 7.5 hp (5.5 kW) single phase VFD, single phase 220V to three phase 380V variable frequency drive for AC motor sp
SKU: GK3000-CS0055G
Free Shipping Worldwide
Delivery date: 6-12 days

Cheap 7.5 hp single phase VFD, converts 1 phase 220-240v 50Hz/60Hz input to 3 phase 380v/ 400v/ 415v output, running three phase motor on single phase household power supply.

Specification:

BasicsModelGK3000-CS0055G
Capacity7.5 hp (5.5 kW)
Shipping weight8 kg
Dimension330*200*200 mm
I/O FeatureRated current14 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0.00~400.00Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Tips: Variable frequency drive installation environment

  • Electrical use conditions:

To prevent electromagnetic wave interference. VFD (Frequency inverter) in the work due to rectification and frequency conversion, around a lot of interference electromagnetic waves, these high-frequency electromagnetic waves on the nearby instruments, instruments have a certain interference. Therefore, the cabinet instrumentation and electronic systems, should be selected metal shell, shielding the VFD to the instrumentation interference. All components should be reliably grounded, in addition to the electrical components, instruments and instruments between the connection should be selected shielded control cable, and the shielding layer should be grounded. If electromagnetic interference is not handled well, it will often make the whole system unable to work and lead to control unit malfunction or damage.

  • Ambient temperature:

The ambient temperature of the variable frequency drive refers to the temperature near the cross section of the VFD. Since the VFD is mainly composed of high-power electronic equipment that is highly susceptible to temperature, the life and reliability of the VFD depends largely on the temperature, which is generally -10℃ to +40℃. In addition, need to consider the VFD's own heat dissipation and the possible extremes of the surrounding environment, for the temperature generally requires a certain amount of margin.