30 hp motor soft starter, 22 kW three phase 240v, 415v, 480v, 690v AC motor starter for choice.
Model | GS2-022 (220v, 240v), GS3-022 (380v, 400v, 415v), GS4-022 (460v, 480v), GS6-022 (575v, 690v). |
Capacity | 30 hp (22 kw) |
Current | 43 amps at 380v/480v, 90 amps at 220v, 30 amps at 690v |
Weight | 5 kgs |
Dimension | 270*146*160 mm |
Input | Voltage | Three-phase 220v, 440v, 480v, 690v AC |
Frequency | 50Hz/ 60Hz |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor |
Starting Times | It is recommended not to exceed 20 times per hour. |
485 Communication | DB9 interface, male plug, ① is RS485+, ⑥ is RS485- |
Control Mode | - Operation panel control.
- Operation panel + external control.
- External control.
- External control + COM control.
- Operation panel + external + COM control.
- Operation panel + COM control.
- COM control.
- No start or stop operation.
|
Start Mode | - Current-limiting to start.
- Voltage ramp to start.
- Torque control + current-limiting to start.
- Torque control + voltage ramp to start.
- Current ramp to start.
- Voltage current-limiting double closed-loop start.
|
Stop Mode | - Soft stop.
- Free stop.
|
Protective Function | - Open loop protection for external instantaneous stop terminals.
- Over-heat protection for soft starter.
- Protection for too long starting time.
- Input open phase protection.
- Output open phase protection.
- Unbalanced three-phase protection.
- Starting over current protection.
- Running overload protection.
- Under voltage protection for power voltage.
- Overvoltage protection for power voltage.
- Protection for fault parameter setting of the soft starter.
- Load short circuit protection.
- Auto restart or incorrect wiring protection.
- Incorrect wiring protection of external control stop terminals.
|
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. |
Temperature | -30 +55 oC |
Humidity | 90%RH without dew condensation. |
Vibration | <0.5G |
Structure | Enclosure | IP 20 |
Cooling | Natural wind cooling. |
Tips: The difference between soft starter and variable frequency drive (VFD)
From the application, the soft starter and variable frequency drive (VFD) are two completely different products. The soft starter is actually a device that controls the voltage and limits the starting current, uses for starting motor and only changes the output voltage amplitude without changing the frequency. And VFD is used for the device needed speed governing, the output not only changes the voltage but also changes the frequency. From the function, VFD has all the functions of the soft starter, so it can be said that VFD is a more powerful soft starter.
Although the soft starter solves the problem of motor starting, but there is no significant energy saving effect. When start using energy-saving operation mode, no-load energy saving is 40%, and load energy saving is only 5%. VFD not only solves the big impact current caused by the motor starting, but also has the good energy saving effect and the frequency conversion ability.
Low cost 30 hp soft starter, 22 kW 3 phase 240v, 415v, 480v affordable motor soft starter direct sale from manufacturer from China.