20 hp soft starter, 15 kW three phase 220v, 380v, 480v, 690v AC motor starter for selection.
Model | GS2-015 (220v, 240v), GS3-015 (380v, 400v, 415v), GS4-015 (460v, 480v), GS6-015 (575v, 690v). |
Capacity | 20 hp (15 kw) |
Current | 30 amps at 380v/480v, 60 amps at 220v, 22 amps at 960v |
Weight | 5 kgs |
Dimension | 270*146*160 mm |
Input | Voltage | Three-phase 240v, 380v, 460v, 690v AC |
Frequency | 50Hz/ 60Hz |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor |
Starting Times | It is recommended not to exceed 20 times per hour. |
485 Communication | DB9 interface, male plug, ① is RS485+, ⑥ is RS485- |
Control Mode | - Operation panel control.
- Operation panel + external control.
- External control.
- External control + COM control.
- Operation panel + external + COM control.
- Operation panel + COM control.
- COM control.
- No start or stop operation.
|
Start Mode | - Current-limiting to start.
- Voltage ramp to start.
- Torque control + current-limiting to start.
- Torque control + voltage ramp to start.
- Current ramp to start.
- Voltage current-limiting double closed-loop start.
|
Stop Mode | - Soft stop.
- Free stop.
|
Protective Function | - Open loop protection for external instantaneous stop terminals.
- Over-heat protection for soft starter.
- Protection for too long starting time.
- Input open phase protection.
- Output open phase protection.
- Unbalanced three-phase protection.
- Starting over current protection.
- Running overload protection.
- Under voltage protection for power voltage.
- Overvoltage protection for power voltage.
- Protection for fault parameter setting of the soft starter.
- Load short circuit protection.
- Auto restart or incorrect wiring protection.
- Incorrect wiring protection of external control stop terminals.
|
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. |
Temperature | -30 +55 oC |
Humidity | 90%RH without dew condensation. |
Vibration | <0.5G |
Structure | Enclosure | IP 20 |
Cooling | Natural wind cooling. |
Tips: Soft starter protection functions
Soft starter has overload protection, open-phase protection, overheating protection, measurement loop parameters and other functions.
- Overload protection: Soft starter introduces a current control loop, so it can trace and detect motor current changes at any time. By increasing the overload current setting and inverse time control mode, it can achieve the overload protection function. When the motor overload, it will turns off the thyristor and send an alarm signal.
- Open-phase protection: While working, the soft starter detects changes in three-phase line current at any time, once the break occurs, it will make a reaction of open-phase protection.
- Overheat protection: Through the soft starter internal thermal relay to detect the temperature of the thyristor radiator, once the radiator temperature exceeds the allowable value, the soft starter will automatically turns off the thyristor and send an alarm signal.
- Measuring loop parameters function: When the motor is working, the detector in the soft starter monitors the running state of the motor all the time, and sends the monitored parameters to the CPU for processing. The CPU will analyze, store and display the monitoring parameters. So the motor soft starter also has the function of measuring loop parameters.
- Other functions: Through the combination of electronic circuits, the soft starter can also achieve various interlock protection in the system.
Cheap price 20 hp soft starter, 15 kW three phase 220v, 380v, 480v AC motor soft start, reduce motor starting current & voltage, protect motor from over-voltage, over-current and phase unbalance etc.