10 hp motor soft starter, 7.5 kW three phase 220v, 400v, 480v, 690v for choice.
Model | GS2-7d5 (220v, 240v), GS3-7d5 (380v, 400v, 415v), GS4-7d5 (460v, 480v), GS6-7d5 (575v, 690v). |
Capacity | 10 hp (7.5 kw) |
Current | 15 amps at 380/480v, 30 amps at 220v, 11 amps at 690v |
Weight | 5 kgs |
Dimension | 270*146*160 mm |
Input | Voltage | Three-phase 220v, 380v, 480v, 690v AC |
Frequency | 50Hz/ 60Hz |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor |
Starting Times | It is recommended not to exceed 20 times per hour. |
485 Communication | DB9 interface, male plug, ① is RS485+, ⑥ is RS485- |
Control Mode | - Operation panel control.
- Operation panel + external control.
- External control.
- External control + COM control.
- Operation panel + external + COM control.
- Operation panel + COM control.
- COM control.
- No start or stop operation.
|
Start Mode | - Current-limiting to start.
- Voltage ramp to start.
- Torque control + current-limiting to start.
- Torque control + voltage ramp to start.
- Current ramp to start.
- Voltage current-limiting double closed-loop start.
|
Stop Mode | - Soft stop.
- Free stop.
|
Protective Function | - Open loop protection for external instantaneous stop terminals.
- Over-heat protection for soft starter.
- Protection for too long starting time.
- Input open phase protection.
- Output open phase protection.
- Unbalanced three-phase protection.
- Starting over current protection.
- Running overload protection.
- Under voltage protection for power voltage.
- Overvoltage protection for power voltage.
- Protection for fault parameter setting of the soft starter.
- Load short circuit protection.
- Auto restart or incorrect wiring protection.
- Incorrect wiring protection of external control stop terminals.
|
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. |
Temperature | -30 +55 oC |
Humidity | 90%RH without dew condensation. |
Vibration | <0.5G |
Structure | Enclosure | IP 20 |
Cooling | Natural wind cooling. |
Tips: Motor soft starter model selection
In actual working should consider the specific product features and technical parameters and product reliability, and according to the actual usage to choose the soft starter. Here it is necessary to differentiate that motor is frequent start or infrequent start. For the soft starter, in general, if the motor start interval time does not exceed 2 minutes, and 30 times per hour, can be identified as infrequent start. Less than 2 minutes should be considered as frequent start. Fan and pump load generally belong to infrequent start. Mechanical transmission type like belt machine, grinding mill, and others can be considered as infrequent start. If the motor is starter, or electromotor that is equipped for the large machinery equipment needing reversible function, mostly belongs to frequent start.
Choosing a soft starter for frequent working place should according to the motor starting current. Normal soft starter silicone controlled rectifier current is 2.5 times of motor rated current. Limit the maximum motor starting current is 4.5 times of the rated current. In the infrequent operation can take full advantage of SCR short-term overload capacity. In the conditions of frequent starting, should select increasing the soft starter capacity, according to the different of frequency take 1.2 to 1.5 times of the capacity. At the same time, due to the SCR frequent working and generating a lot of heat, the soft starter must be equipped with mechanical air-cooled to dissipate heat. It is best to put a mechanical air-cooled soft start device for each switchgear, and the switchgear should also be set with mechanical ventilation.
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.