Description
- 8kW (10kVA) 1 phase or 3 phase diesel generator is available, portable and silent design.
- High quality 12V 30AH without maintenance battery for easy startups.
- With single cylinder, 4-stroke air cooled diesel engine and full copper wire alternator ensure more stable operation.
- Brushless alternator eliminates time consuming maintenance.
- All kinds of sockets, 50Hz/60Hz AC voltages, ATS panel for selection.
- CE, ISO9001-2000 aprroved, 1 year warranty.
Specifications
Model | DG11000SE |
Generator | Frequency | 50Hz | 60Hz |
AC Voltage | 120V, 220V, 230V, 120/240V, 220/380V, 230/400V |
Rated AC Output | 7.5kW | 8kW |
Max. AC Output | 8kW | 8.5kW |
Power Factor (cosΦ) | cosΦ=0.8 |
Alternator Type | Self-excited |
Continuous Working Time | 12h |
DC Output | 12V 8.3A |
Phase | Single or Three phase |
Noise Level at 7m | 70-73dB |
Fuel Tank Capacity | 30L |
Starting Battery | 12V 30AH *The starting batteries cannot be carried by air so you need to purchase it separately. |
Certificate | CE, ISO |
Engine | Model | HR198FA |
Engine Type | Single-cylinder, vertical, 4-stroke air-cooled diesel engine |
Bore*Stroke | 98*84mm |
Displacement Capacity | 633cc |
Fuel | 0# or -10# light diesel oil |
Lubrication Oil Volume | 1.63L |
Combustion System | Direct injection |
Standard Configuration | - Voltmeter*1
- AC output socker*2
- AC circuit breaker*1
- Oil warning light*1
- Oil alert*1
|
Optional Configuration | - DC circuit breaker
- Calculagraph
- Big wheel
- Three phase voltage
- Current meter
- ATS
- Remote control
*Please contact us if you need the above options. |
Dimensions | Dimension (L*W*H) | 1130*760*860mm |
Gross Wight | 230kg |
Tips: Portable diesel generator maintenance
The routine maintenance cycle of small and portable diesel generator set is divided into daily, weekly, semi annual and annual maintenance. These Regulations are detailed in the general instructions. The maintenance personnel can ensure the normal operation of small diesel generator set as long as they comply with them.
If the unit is usually only in no-load or light load trial operation, and the load is more than 5% of the rated load, the unit shall be started for at least 4 hours a year. For the standby portable diesel generator set, at least once every half a year shall simulate the mains power outage, verify the starting performance and expected rated bearing capacity of the unit, check the automatic switch and relevant configuration of the standby power supply. A more thorough maintenance shall be carried out once a year, including change oil, oil filter, clean air filter and diesel filter. In addition, in order to ensure the safe and reliable operation of the diesel generator motor, the motor must be overhauled. The overhauling items include winding condition test and bearing inspection. In addition, the oil engine must be checked before and during operation.
10kVA (8kW) air-cooled diesel generator, silent and small generator for home use. Electric start with 30AH battery, DC 12V 8.3 Amps charging facility, 30L large fuel tank, ensuring 12 hours of continuous output. ATO provides single phase and three phase portable generator and the AC output voltage can be customized.