One-phase 0.55kW regenerative blower can output 95m³ large air volume per hour. 57 decibels low noise, more comfortable to use.
Specification
Model | CHN-2PB310A01 |
Phase | 1 |
Frequency | 50 |
Power | 0.7 hp (550W) |
Voltage (AC) | 220-240V |
Current | 3.7A |
Max airflow | 95 m³/ h (56 cfm) |
Rated vacuum pressure | -120 mbar |
Rated compress pressure | 130 mbar |
Noise | 57 dB (A) |
Weight | 16 kg |
Dimention (Unit: mm)

A | B | C | D | E | F | G | H | J | K | L | M | N | O | P | Q | ΦR | S | U | V (1~) | V' (1~) | V1 (3~) | V1' (3~) | YXZ | X-HOLES | ΦX |
268 | 272 | 93 | 205 | 2 | 260 | 92 | 141 | 101 | 83 | 108 | 82 | 69 | 41 | G11/4 | 64 | 10 | 3 | M6X17 | M25X1.5 | M16X1.5 | / | / | M6X15 | 0°/ 120°/ 240° | 160 |
Tips: ATO high pressure regenerative blower buying tips
- Before selecting a high pressure regenerative blower, you must fully consider the type, standard, special purpose of various regenerative blowers, the development and promotion of new regenerative blowers, etc., and also fully consider the requirements of environmental protection in order to purchase the best vortex blowers. Choose blowers for different purposes: If you transport explosive and flammable gases, you should choose explosion-proof vortex blowers. Dust exhaust or pulverized coal vortex blowers should be selected when exhausting dust or transporting pulverized coal. Anti-corrosion vortex blowers should be selected when transporting corrosive gases. High-temperature vortex blowers should be selected when working in high-temperature situations or when transporting high-temperature gases.
- Depending on the physical and chemical properties of the air transported by the high pressure blowers. The one with higher power, smaller machine number, and larger adjustment plan should be selected first.
- Assuming that the diameter of the selected blower impeller is much larger than that of the original blower, it is necessary to calculate the recommended time of the motor, the strength of the original parts of the blower, and the critical speed of the shaft.
- When choosing a centrifugal blower, it is not necessary to install a valve that is only recommended. When selecting a centrifugal blower for discharging high-temperature flue gas or air, the recommended valve should be installed to prevent overload during cold operation. The first choice should be a blower with high power and low impeller peripheral speed.
- For the ventilation system with noise reduction requirements, it should be operated at the power point, and corresponding noise reduction and vibration reduction methods should be adopted according to the transmission method of noise and vibration generated by the ventilation system. The vibration damping method of blowers and motors generally can choose a vibration damping foundation such as a spring shock absorber or a rubber shock absorber. You should try to prevent the use of blowers in parallel or series operation. When it is unavoidable, wind turbines of the same type and function should be selected for joint operation. When series connection is selected, there should be a certain piping combination between the first-stage blower and the second-stage blower.
Buy good price 220V high pressure regenerative blower from ATO. The motor works at single phase, 0.7 hp (550W) power and the air output volume up to 56 cfm. -120 mbar rated vacuum pressure, 130 mbar rated compress pressure. The front bearing design increases the working stability.