Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
80 hp Single Phase to Three Phase Converter
 
Close
Shopping Categories
Search

80 hp Single Phase to Three Phase Converter


$31240.29
1 Phase to 3 phase converter for sale, 80 hp (60 kW) static phase converter convert from 220 volt single to 3 phase, with LCD
SKU: CHN-PHC-80
Free Shipping Worldwide
Delivery date: 6-12 days

Professional digital display singel phase to 3 phase converter, 80 hp single 240 volt to 415 volt 3 phase converter, frequency 50 or 60Hz, other phases and voltages can be customized.

Note: When the load is a motor, the phase converter should be more than 3 times the motor capacity.

Specification:

ModelCHN-BZT-60kW
Isolation ModeLow frequency transformer
Input VoltageOptional: 110V/ 120V/ 220V/ 230V/ 240V/ 415V/ 440V/ 480V) single phase 2 wire
Output VoltageOptional: 220V/ 380V/ 400V/ 415V/ 440V/ 480V) 3 phase 4 wire+PE
Input Current184.5A at 230V (Input Current=Power/Input Voltage/1.414)
Rated Output Power80 hp (60 kW)
Output WaveformPure sine wave
Output Current86.6A at 400V
Frequnecy50Hz or 60Hz
Power Factor1
Overload Ability150%, 5 Seconds
Efficiency>93%
Waveform Distortion Rated (THD)≤3%(Linear load)
Dynamic Respond (0 to 100% load)5%, ≤50ms
DisplayLCD
Running ModeWorking continously
Electrical Inslation Properties2000Vac, 1 Minute
Communication InterfaceRS485 (Optional)
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
Cooling MethodForced air cooling
Short Circuit ProtectionNo automatic recovery, need to restart the machine
Noise (1 meter)≤50dB
Degree of ProtectionIP20 (indoor)
Working Altitude≤2000m
Woorking Temperature-25~+55°C
Relative Humidty0~90%, Non condensing
Dimension750*750*1480mm
Weight590kg

Single Phase
Single phase
Split phase
Split phase

Feature

1. Single phase to 3 phase converter input voltage, output voltage, frequency and phase can be customized.
2. Pure sine wave output, transient response is less than 50ms, waveform distortion is minimal, conversion efficiency is high, and output voltage is stable.
3. The static phase converter uses a low frequency transformer to ensure that the input voltage and output voltage are completely electrically isolated to avoid interference.
4. Using SVPWM space vector algorithm, high conversion efficiency, high instantaneous power, low no-load loss, conversion efficiency can reach more than 94%, and no-load loss is small.
5. The output AC power supply is suitable for all types of appliances, power tools, motors, etc. Has a higher driving load capacity.
6. 3 Phase converter has the function of filtering out grid interference and interference at the same time, with stable voltage and frequency power performance, and provides a more stable and pure power supply environment for back-end equipment.
7. Complete output protection function, with output overvoltage, overload, short circuit, overheating, self-diagnostic protection and other protection functions.
8. High conversion efficiency, high instantaneous power and low load loss.
9. Two start modes: step-down start and variable frequency start. Customers can set the startup mode according to the load type. Reduce the use of frequency converters, thereby reducing equipment investment costs, easy wiring and control.

single phase to three phase power converter

Tips: Harm of three-phase power imbalance

In a three-phase power supply system, because some electrical equipment is only suitable for single-phase power consumption, such electrical equipment is connected to the power grid. Improper arrangements will cause three-phase current imbalance. Unbalanced current will cause different voltage drops in each phase of the system, resulting in unbalanced three-phases of the grid voltage. Its main hazards are:
1. For the induction motor, due to the imbalance of the three-phase voltage, a reverse-order rotating magnetic field will be generated on the stator of the induction motor. At this time, the induction low-end machine operates under the action of the positive and negative rotating magnetic fields. Because the positive-sequence rotating magnetic field is much larger than the reverse-sequence rotating magnetic field, the rotation direction of the motor still rotates in the positive-sequence direction. However, the reverse sequence current of the rotor is large. Due to the existence of the reverse sequence current and the magnetic field, a large reverse sequence braking torque will be generated, which will greatly reduce the output power of the motor, and the motor winding will overheat.
2. In transformer and distribution equipment, the power loss will increase. All generators, transformers and other electrical equipment are designed under three-phase load balancing conditions. If one phase in the three-phase circuit is abnormal, it is called phase loss. When it appears, the motor will vibrate or rotate weakly and have a lot of noise. If the controller is operated under phase loss, it will be easy to burn or start.