3 Phase 3-Wire SCR Power Regulator


$187.46
SCR power regulator is mainly used for power & voltage regulation and temperature control in electric power system. Rated
SKU: CHN-PRG-3320
Free Shipping Worldwide
Delivery date: 6-12 days

Features

  • Linear phase shift control circuit control circuit, good stability and high accuracy. Modular, high pressure resistant, anti-interference.
  • Protection method is built-in fast fuse.
  • Adopts vacuum welding technology, optimized heat dissipation, good quality, long service life, safety and reliability.
  • With multi-function LED to indicate working status.

Specification

ModelCHN-AYSCR-LACHN-J3SCR-LA
Rated Voltage3 Phase 380VAC3 Phase 380VAC
Wires3 Phase 3-Wire3 Phase 3-Wire
Rated Current25A40A75A90A
LoadY connection method (220V AC)8kW13kW23kW30kW
▲ connection method (380V AC)14kW22kW40kW50kW
Auxiliary Power-220VAC
Control Signal4-20mA, 0-5VDC, 0-10VDC4-20mA, 0-5VDC, 0-10VDC
(3 ways can switch)
Protection Functionfast fuse
CertificationCE
Operation Frequency50Hz/60Hz
Output Modephase output
Use Environmenttemperature<45℃
humidity<90%RH

Star (Y) Type Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator

Star Type Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator

 

Triangle Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator

Triangle Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator

 

Phase Output of 3 Phase 3-Wire SCR Power Regulator

Precautions

  1. Main circuit uses 3-phase 3-wire input, no phase sequence is required.
  2. SCR is high current product, please be sure to lock the (R.S.T) and (U.V.W) terminals, otherwise the terminals will heat up and the SCR will burn out.
  3. SCR has a built-in fast fuse for over current and short circuit protection. If the fuse is blown due to overcurrent, first check the load for faults such as short circuit and partial discharge. After troubleshooting, open the panel and replace it. Be sure to replace it with fuse of the same specification. Be careful not to increase amperage of the fuse at will.
  4. When using the load Y type wiring method, center point cannot be connected to zero line, otherwise the SCR will lose control. If 3-phase load is unbalanced, center point must be connected to zero line.