Single pole DC contactor has one normal open (SPST-NO) contact, 600A high rated current, particularly used for electric vehicle, telecommunication equiment, car batteries, trains, ships, electronic control system.
Features
- 600 amps rated load current of contact circuit.
- 12V, 24V, 48V DC coil rated voltage for selection.
- Continuous operation duty.
- Easy and quick installation, available any way to install.
- Mechanical life up to 300 thousand times.
Specifications
Basics | Model | CHN-AZJ600 |
Body Size | 130*82*110 mm |
Weight | 1510 g |
Technical Parameters | Coil Rated Voltage | 12V/24V/48V |
Rated Load Voltage | 12~72V DC |
Contact Circuit Rated Load Current | 600 A |
Contact Form | 1 NO |
Overload Current | ≤7 le |
Coil Power | ≤12 W |
Main contact voltage drop at 100A | ≤100 mV |
The Allowed Range of Coil Voltage | ±20% |
Pull-In Time (N/O Contacts to Open) | ≤30 ms |
Drop-Out Time (N/O Contact to Close) | ≤20 ms |
Insulation Resistance | ≥50 MΩ |
Work Duty | Continuous |
Dielectric Withstanding Voltage | 50Hz/60Hz 1500VAC/Min |
Auxiliary Contact Rated Load (Option) | 2A/48VDC, 5A/24VDC |
Electric Life | Continuous 20000 times |
Mechanical Life | 300 thousand times |
Environment | Operating Temperature | -25℃~55℃ |
Operating Humidity | 5~95% RH |
International Protection | IP 50 |
DC Contactor Circuit Diagram
Installation Diagram (Unit: mm)
Tips: Iron core of the contactor can't suck up, how to solve?
Possible causes of the fault:
- Low power supply voltage.
- Something is wrong with the contactor's control loop or the power supply can't be connected.
- Contactor coil is broken or burned.
- The contactor magnet is partly inflexible or the moving contact gets stuck.
- Pressure of the contact spring is too large.
Maintenance method:
- If there's a huge difference between the measured value and the coil's rated voltage, look up the reason from the power supply and adjust the voltage to the normal value.
- Correct the contactor's control loop and connect it by the correct line; replaced the damaged electrical components.
- Measure the coil resistance with a multimeter, if the current is too large, the coil shorts or breaks, please replace the coil.
- Repair the mechanical fault of the contactor, remove the rusty part, add some lubricating oil to the movement mechanism; replaced the damaged electrical components.
- Adjust the contact spring pressure according to technical requirements.
High current contactor, designed for DC loads, contact circuit rated load current is 600A, one normally open contact which has excellent conductivity. Single pole contactor, cheap price and manufacturer direct sale.