3 Pole Molded Case Circuit Breaker, 50A/ 60A/ 75A/ 100A


$47.23
High quality molded case circuit breaker is intended for the short circuit and overload protection in the AC 50/60Hz circuit,
SKU: CHN-MCCB-1003P
Free Shipping Worldwide
Delivery date: 6-12 days

Mccb circuit breaker with IP20 protection degree, rated voltage 380/ 415VAC, 50Hz/ 60Hz. 100 amp mccb has advantages of high reliability, low failure rate, long overhaul period and low maintenance workload.

Molded Case Circuit Breaker Information

  • Model: CHN-ABE-103b
  • Rated Current: 100 amp
  • Rated Voltage: 380/415V AC, 50Hz/ 60Hz
  • Number of poles: Three pole
  • 50 kA short circuit interrupting capacity

Specification

Standard CertificationsIEC60947GB14048
Electrical ParametersModelCHN-ABE-103b
Rated Current50A, 60A, 75A, 100A (contact us, the current can be chosen)
Numbers of Poles3 Pole
Rated Operating Voltage400V
Rated Insulated Voltage (Ui)800V
Rated Frequency50Hz/ 60Hz
Ultimate Short Circuit Breaking Capacity, IcuDC125V10kA
250V5kA
AC 50Hz/ 60Hz230V25kA
380V14kA
415V10kA
440V10kA
480V7.5kA
600V5kA
Mechanical ParametersElectrical Life1500 times
Mechanical Life8500 times
Protection DegreeIP 20
Operating Temperature-25℃~+50℃
Weight0.8kg

Dimension (Unit: mm)

 Diemension of molded case circuit breaker      Diemension of molded case circuit breaker 1 Diemension of molded case circuit breaker 2     

ModelDimensionsMounting Dimensions
CC1EFGG1HH1H2H3H4H5LL1L2WW1W2ABΦd
CHN-ABE-103b8712450.52219.57.56810218544.51501851329230120361427

Tips: Working Principle of Molded Case Circuit Breaker.

The main contact of the low-voltage circuit breaker is manually operated or electrically closed. After the main contact is closed, the free trip mechanism locks the main contact in the closing position. The coil of the overcurrent release and the thermal element of the thermal release are connected in series with the main circuit, and the coil of the undervoltage release is connected in parallel with the power supply.

When the circuit is short-circuited or severely overloaded, the armature of the overcurrent release pulls in, causing the free tripping mechanism to operate, and the main contact disconnects the main circuit.

When the circuit is overloaded, the thermal element of the thermal trip unit generates heat to bend the bimetallic strip, pushing the free trip mechanism to act, and the main contact disconnects the main circuit.

When the circuit is under-voltage, the armature of the under-voltage release is released, which also causes the free trip mechanism to act, and the main contact disconnects the main circuit.

When the shunt trip button is pressed, the armature of the shunt trip unit pulls in, causing the free trip mechanism to act, and the main contact disconnects the main circuit.