Mccb circuit breaker with rated frequency 50Hz/ 60Hz, 1500 times electrical life, 8500 times mechanical life. The 100 amp mccb breaker has advantages of small size, light weight and long service lifetime.
Molded Case Circuit Breaker Information
- Model: CHN-ABE-102b
- Rated Current: 100 amp
- Rated Voltage: 380/415V AC, 50Hz/ 60Hz
- Number of poles: Two pole
- 50 kA short circuit interrupting capacity
Specification
Standard Certifications | IEC60947 | GB14048 |
Electrical Parameters | Model | CHN-ABE-102b |
Rated Current | 10A, 15A, 20A, 30A, 40A, 50A, 60A, 75A, 100A (contact us, the current can be chosen) |
Numbers of Poles | 2 Pole |
Rated Operating Voltage | 400V |
Rated Insulated Voltage (Ui) | 800V |
Rated Frequency | 50Hz/ 60Hz |
Ultimate Short Circuit Breaking Capacity, Icu | DC | 125V | 10kA |
250V | 5kA |
AC 50Hz/ 60Hz | 230V | 25kA |
380V | 14kA |
415V | 10kA |
440V | 10kA |
480V | 7.5kA |
600V | 5kA |
Mechanical Parameters | Electrical Life | 1500 times |
Mechanical Life | 8500 times |
Protection Degree | IP20 |
Operating Temperature | -25℃~+50℃ |
Weight | 0.6kg |
Dimension (Unit: mm)

Model | Dimensions | Mounting Dimensions |
C | C1 | E | F | G | G1 | H | H1 | H2 | H3 | H4 | H5 | L | L1 | L2 | W | W1 | W2 | A | B | Φd |
CHN-ABE-102b | 87 | 124 | 50.5 | 22 | 19.5 | 7.5 | 68 | 102 | 18 | 5 | 4 | 4.5 | 150 | 185 | 132 | 92 | 30 | 120 | 36 | 142 | 7 |
Tips: What is a Molded Case Circuit Breaker?
Molded case circuit breakers are also called device-type circuit breakers. All parts are sealed in a plastic case. The auxiliary contacts, undervoltage releases and shunt releases are mostly modularized. Due to the very compact structure, the molded case circuit breaker cannot be overhauled. It mostly adopts manual operation, and large capacity can choose electric opening and closing. Due to the application of electronic overcurrent releases, molded case circuit breakers can also be divided into two types: A and B. Type B has good three-stage protection characteristics. However, due to price factors, thermal magnetic releases are used. Class A products have a higher market share. Molded case circuit breaker is the contact, arc extinguishing chamber, trip unit and operating mechanism are all installed in a plastic shell. Generally, maintenance is not considered. It is suitable for branch circuit protection switch. The overcurrent release has thermomagnetic There are two kinds of type and electronic type. Generally, the thermal magnetic molded case circuit breaker is a non-selective circuit breaker, and only has two protection methods: overload long delay and short circuit instantaneous protection. Four protection functions: time delay, instantaneous short circuit and ground fault. Some of the newly launched products of electronic molded case circuit breakers also have a regional selective interlocking function. Most molded case circuit breakers are manually operated, and some have motor operating mechanisms.
2 pole molded case circuit breaker with 20A/ 30A/ 40A/ 50A, max. current 100 amp for selection, rated operating voltage 400V, rated insulated voltage 800 volt. The molded case breaker is suitable for conversion of line and infrequent starting motor.