Features
- DC 12-900V rated load voltage of contact circuit.
- SPST-NO of contact form, 12 volt, 24 volt coil for selecting.
- Main contact voltage drop at 250A, not above 100mV.
- The connection of contact and coil need to be nonpolarity.
- Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
- The joint way of the coil is very convenient.
- The coil has no counter force of electromagnetism.
- Compare to the similar products, this product is smallest and lightest.
Specifications
Basics | Model | CHN-ADH250 |
Dimension | 80 x 65 x 74 mm |
Weight | 480 g |
Main Contact Parameters | Contact Form | 1 NO |
Leading-Out | M10 Internal thread |
Rated Load Current | 250 A |
Rated Load Voltage | 12 – 900V DC |
Maximum Switching Current | 2000A 320V DC (≥1 times) |
Maximum Switching Power | 640 kW |
Coil Parameters | Standard Type Voltage | 12/24V DC |
Work Voltage | 8~36V |
Max Voltage | 36 V |
Coil Resistance | 3.1Ω |
Average Holding Current | 0.14 A |
Steady State Power | 1.7~2 W |
Actuation Time | ≤30 ms |
Release Time | ≤10 ms |
Bounce Time | ≤5 ms |
Mechanical Specification | Stability | 196 m/s2 (20G) |
Strength | 490 m/s2 (50G) |
Vibration | 80 ~2000Hz 98m/s2 (20G) |
IP Grade | IP67 |
Environment | Operating Temperature | -40℃~85℃ |
Operating Humidity | 5~95% RH |
Installation Diagram (Unit: mm)

High Voltage DC Contactor Coil Schematic
Tips: The contactor makes large noise when it works, how to solve?
Possible causes of the fault
- The contactor works in high temperature for a long time.
- The contactor is frequently operated.
- Contact over range is too small.
- The contact surface has impurities or is not smooth.
- Pressure of contact spring is too small.
- The three phase contact can't contact synchronously; short circuit at the load side.
Maintenance method
- Measure with a multimeter whether the power supply voltage of a contactor coil is lower than the required rated voltage, if lower, find causes on the circuit and adjust the voltage to the normal value.
- Grind the suction face of the contactor with fine sand paper, clean up the sundries, spray few oil on the end face when necessary and then reassemble.
- Reassemble and repair the contactor's action mechanism.
- Weld the short-circuit ring and connect again.
- Replace the contactor's iron core.
- Reset the spring pressure of the contactor to a proper value.