Close
Shopping Categories
Search

100A High Voltage DC Contactor, 12V/24V coil


$118.92
The CHN-ADH100 contactor is specially design to meet the requirements of high voltage DC switching applications. Available w
SKU: CHN-DCCON-HV100
Free Shipping Worldwide
Delivery date: 6-12 days

Features

  • DC 12-900V rated load voltage of contact circuit.
  • normally open type (SPST-NO), 12 volt, 24 volt coil for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • The connection of contact and coil need to be nonpolarity.
  • Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
  • The joint way of the coil is very convenient.
  • The coil has no counter force of electromagnetism.
  • Compare to the similar products, this product is smallest and lightest.

Specifications

BasicsModelCHN-ADH100
Dimension55 x 42 x 62 mm
Weight230 g
Main Contact ParametersContact Form1 NO
Leading-OutM5 internal thread/18 mm
Rated Load Current100 A
Rated Load Voltage12 – 900V DC
Maximum Switching Current1000A 320V DC (≥1 times)
Maximum Switching Power320 kW
Rated Electric Life10,000 times
Coil ParametersStandard Type Voltage12V DC24V DC
Work Voltage9~16V18~32 V
Max Voltage16 V32 V
Coil Resistance26 Ω96 Ω
Average Holding Current0.46 A0.25 A
Steady State Power5.5 W6 W
Actuation Time≤25 ms
Release Time≤10 ms
Bounce Time≤5 ms
Mechanical SpecificationStability196 m/s2 (20G)
Strength490 m/s2 (50G)
Vibration80 ~2000Hz 98m/s2 (20G)
IP GradeIP67
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

Installation Diagram (Unit: mm)
high voltage 50a dc contactor dimension 1high voltage 50a dc contactor dimension 2High Voltage DC Contactor Coil Schematic
high voltage dc contactor coil schematicTips: Contacts of DC contactor

In the selection of a DC contactor, control method of the application circuit shall be considered firstly, as well as the role of the contactor in the circuit, because the main contact of DC contactor includes two types of single and double. Single contact contactor is mainly used in electric system, or other independent variable current systems, its functions are: 1 Ready to run; 2 Quickly cut off main circuit in case of accident state. Therefore, the rated current, rated voltage and arc breaking capacity of the contactor must meet the system requirements. Double contacts contactor is mainly used for non independent power supply system or bilateral system, pay attention to the rated current, rated voltage and arc breaking capacity. Finally, the coil suction voltage shall comply with the requirements of operating system. When the suction coil is large, add RC absorption loop to prevent the self-inducing potential to break through itself or relevant equipment.