350 Amps Isolator Switch, 3 Pole/ 4 Pole


$199.89
High performance 350 Amps Isolator switch for sale, can choose from 3 pole or 4 pole, rated insulation voltage 690V. Widely u
SKU: CHN-IS-HGL350A
Free Shipping Worldwide
Delivery date: 6-12 days

3 Pole or 4 pole isolator switch rate current 350A, used for infrequent connection and segmentation circuit and electrical isolation. Good quality and low price, manufacturer direct sale.

350A Isolator Switch Specifications

BasicsModelATOHGL-350A
Pole3 Pole/4 Pole
Weight3 Pole4.3 kg
4 Pole4.3 kg
Technical ParametersRated current350A
Rated insulation voltage Ui690V
Dielectric strength1890V
Rated surge-resistant voltage Uimp kV (installed category IV)6
Rated working current le380VAC-21315A
AC-22315A
AC-23315A
660VAC-21315A
AC-22315A
DC-23125A
220VDC-21315A
DC-22315A
DC-23 315A
440VDC-21315A
DC-22315A
DC-23315A
Motor power P(380V) kW380V160 kW
660V185 kW
Rated short-time withstand current lcw (kA rms)0.1s/ 1.0s12.5
Rated breaking capability Icn (Arms) AC23 380VA2520
Rated making capacity Icm (Arms) AC23 380V3150
Rated short-current making capacity Icm' (Kapeak value)25.2
Mechanical durability (number of cyclic operation)10000
Electric durability Ue=660V, Rated currentCOSφ=0.95AC211700
COSφ=0.65AC22100
COSφ=0.35AC23500
Working EnvironmentMoment of operation1.2 Nm
Temperature-5℃~+55℃
Way of workingContinuously working
OperatingHandle
Installation formVertical
Altitude≤2000m
Pollution level3
Overvoltage level

Operation Mode

Load Isolator Disconnect Switch

Tip: Precautions for isolator switch operation

1. During the overhaul of electrical equipment, provide an electrical interval and a clearly visible disconnection point to ensure the personal safety of maintenance personnel.
2. Isolating switch cannot be operated with load: it cannot be operated with rated load or large load, load current and short-circuit current cannot be divided or combined, but the circuit with small load and no-load circuit can be operated with arc extinguishing chamber.
3. In general power transmission operation: first close the isolating switch, then close the circuit breaker or load switch; when the isolating switch is powered off: disconnect the circuit breaker or load switch first, and then disconnect the isolating switch.
4. The selection is the same as other electrical equipment, and its rated voltage, rated current, dynamic stable current, thermal stable current, etc. must meet the needs of the use occasion.