EMI Line Filter, 100A, 3 phase


$238.15
100A 3-phase single-stage EMI power line filter, rated voltage 250/440V AC, compact size, easy to install with stud connecti
SKU: CHN-EMI-10100
Free Shipping Worldwide
Delivery date: 6-12 days

100A 3-phase 3-wire single-stage EMI power line filter with excellent attenuation performance is widely used in the industrial automation equipment, such as 3 phase motor drives, printing equipment, packaging equipment, textile equipment, industrial air conditioners, UPS and so on.

Specification

ModelCHN-MT710-100
Filter TypeEMI
ConfigurationSingle Stage
Rated Current @ 40℃100A
Rated Voltage250/440V AC
Operating Frequency50/60Hz
PhaseThree Phase Three Wire
Leakage Current≤10mA @ 250V AC 50Hz 20℃
Filter Range150KHz-30MHz
Hipot Rating (one minute)Line to Line1450V DC
Line to Ground2250V DC
Climatic Category25/085/21
Working Temperature-25°C~+85°C
Output TermainalThreaded stud M8
Weight3kg
DimensionSee below

Dimensions (Unit: mm)

100A 3-phase EMI Line Filter Dimension

Electrical Schematic

Three Phase EMI Filter Electrical Schematic

Insertion Loss Table (in 50Ω system acccording to IEC/CISPR No.17)

6A 10A 20A 30A Power Line Filter Insertion Loss Table

40A 50A 100A EMI Line Filter Insertion Loss Table

Tips: Difference between Reactors and Filters

A filter is a network with selection for frequency. It can allow AC electricity at certain frequency band to pass through smoothly, and have much attenuation for AC electricity at other frequency band.

The line reactor is an air core coil with non-magnetic material. It has three assembling type according to requirement, that is vertical, horizontal and delta shape. When short circuit happens in power system, it will generate big value short current. Without restraining, it will be difficult to keep electrical equipment dynamic stable and heat stable. Therefore, in order to satisfy breaking capacity requirement of some circuit breaker, usually connect reactor in series at outgoing circuit breaker position, to increase short-circuit impedance and restrain short-circuit current.

As a result of using a reactor, when short circuit occurs, reactor voltage drop is large and it plays a role of maintaining bus line voltage level to make the voltage in small fluctuation, which guarantees electrical equipment work stably in non-fault line. In all, passive filter is composed of reactor, capacitor, sometimes resistor required. That is, reactor is only an element of filter. Of course for low pass filter (wave resistance) or high pass filter (trapping wave), they could be composed of single reactor. Reactor can be used in filter, also for resonant loop, output reactive current, limit current etc.