CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
6A EMI Power Line Filter, 1 Phase
 
Close
Shopping Categories
Search

6A EMI Power Line Filter, 1 Phase


$80.25
6 Amp single-phase single-stage power line filter, rated voltage 115/250V AC 50/60Hz, general purpose EMI/RFI filter for vari
SKU: CHN-EMI-2106
Free Shipping Worldwide
Delivery date: 6-12 days

1-phase 1-stage EMI power line filter with rated current 6A and rated voltage 250V AC, is designed for general purpose for power line filtering with excellent attenuation performance in electrical equipment, electronics, household appliances, and office equipment and other equipment.

Specification

ModelCHN-MT210-6
Filter TypeEMI
ConfigurationSingle Stage
Rated Current @ 40℃6A
Rated Voltage115/250V AC
Operating Frequency50/60Hz
PhaseSingle
Leakage Current≤0.8mA @ 250V AC 50Hz 20℃
Hipot Rating (one minute)Line to Line1450V DC
Line to Ground2000V DC
Climatic Category25/085/21
Working Temperature-25°C~+85°C
Output TermainalLead wire
Weight65g
DimensionSee below

Insertion Loss Table (in 50Ω system acccording to IEC/CISPR No.17)
Single phase power line filter 1A-10A insertion loss

Dimensions (Unit: mm)

Single phase power line filter 1A-10A dimension

Electrical Schematic

1A-6A 1-phase EMI line filter electrical schematic

Tips: 3 notices for installing an EMI power line filter

1. To make sure EMI line filter to work safely and reliably(dissipation and filtering effect), it must install EMI power line filter on the equipment frame and housing, and also need to guarantee GND of EMI line filter and GND of equipment housing conforming with each other, shortening the ground wire of EMI filter as possible as it could. If GND is not at the same place, when leakage current and noise current of EMI filter flow through the two GND places, then it will lead noise into other parts inside equipment. Besides, grounding wire of EMI line filter will lead in impedance, and it may lead to high frequency attenuation performance damage of EMI filter. Therefore, EMI line filter with metal housing should directly connect with machine housing. If housing is painted, it then must remove the painting layer. If EMI filter with metal housing which can’t connect with ground directly or use EMI power line filter with plastic housing, the grounding wire with equipment housing should be as short as possible.

2. EMI power line filter should be installed at equipment power line input end, and the connecting wire should be as short as possible. Power supply inside the equipment should be installed at EMI line filter output end. If the input wire of EMI filter inside the equipment is long, input wire at high frequency end would couple the led in conducting interference to other parts. If power inside the equipment is installed at EMI line filter input end, it may lead to the same result as the connecting wire is too long.

3. Make sure EMI power line filter input wire and output wire separate. If EMI line filter input, input wire tie up together or install too close between each other, then because of the coupling among them, it may lead to EMI line filter high frequency attenuation reducing. If input, output wire must approach, the twisted pair or shielded line should be used.