Model | CHN-VMC-68S-10AD24 |
Reated Voltage | 20-50VDC |
Motor Voltage | 24V |
Rated Current | 10A |
Limit Current | 12A |
Support Maximum Speed | Speed above 20000 rpm, the specific speed depends on the motor itself and the load |
Speed Mode | 1. Control panel potentiometer: use this potentiometer to adjust the speed 2. External potentiometer: connect the potentiometer to the terminal block behind the controller for speed regulation 3. External 5V speed regulation voltage: Connect 5V speed regulation voltage from the terminal block on the back of the controller |
Speed Output | PG signal: There is a 5V speed pulse output between this port and the ground. The output frequency is set to P (Hz), the number of motor stages is N, and the speed is F (RPM), then the output speed frequency: P=F*N/60 |
Alarm Output | ALM signal: There is an alarm pulse output between this port and the ground 1. In normal operation, this port outputs 5V high level 2. When it is turned on, but the speed control signal is very low and the motor does not rotate, the port signal is low, that is: when the EN enable key is turned on, as long as the motor does not rotate, the alarm port signal is always low , Prompting that the current status is abnormal or there is a question, to be dealt with 3. In the case of undervoltage, overvoltage, locked rotor, phase loss, phase short circuit, etc., the port signal is low level |
Forward and Reverse Function | F/R: An external switch is connected to the corresponding position of the rear terminal block, one end of the switch is connected to the F/R port, one end is grounded, the switch is turned on and off, and the rotation direction of the motor can be changed |
Start Stop | 1. Toggle switch on the panel 2. Connect the switch to the corresponding position of the rear terminal block to control the start and stop Note: The two methods cannot be used at the same time. When using one method, the switch of the other method should be in the on position |
Locked Rotor Protection | When the motor is locked, the motor stops working and restarts when the power is turned on |
Power Light | Green light: always on when power is on |
Status Light | Red light When the boot is enabled, the potentiometer or the external voltage is not turned on, and it is in the semi-standby state, it flashes once at an interval Enable is not turned on, in standby state, flashes seven times at intervals |
Insulation Resistance | Under normal temperature and pressure>100MΩ |
Dielectric Strength | 0.5KV at normal temperature and pressure, 1 minute |
Storage Temperature | -20℃~ +65℃ |
Use Occasions | Avoid direct contact with dust, oil fume and corrosive gases |
Operating Temperature | 0-45℃ |
Humidity | <80%, no frost, no frost |
Shock | 5.9m/S² MAX |
Storage Humidity | 0~95%RH |
Volume | 110mm(length)*54mm(width)*118mm(height) |
Weight | 0.8kg |