CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
5 hp (4 kW) VFD, Single Phase Input & Output
 
Close
Shopping Categories
Search

5 hp (4 kW) VFD, Single Phase Input & Output


$649.54
Low cost 5 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 23 amps, manufacturer direct sale.
SKU: GK3000-1S0037
Free Shipping Worldwide
Delivery date: 6-12 days

5 hp variable frequency drive, 4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0037
Capacity5 hp (4 kW)
Shipping weight8 kg
Dimension330*200*200 mm
I/O FeatureRated current23 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequencyV/f control: 0~500Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/f control
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Starting torque1 Hz/150%
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
DC brakingDC braking when starting and stopping
DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note: The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
Tips: Six attentions of installing VFD in automatic control system

  1. For the frequency given signal should be used as far as possible 4-20mA international standard signal. Should make sure the signal line shield ground, to avoid the interference signal into the VFD. The production site has an interference signal, the interference signal will affect the stability of the control, so need to use input filter, and set its range to be 0.00-5.00s. If using VFD built-in PID function should use the feedback filter to increase the control stability of the built-in PID, the setting range is 0.0-60s. However, it should be noted that the filter time is set too long, the control is stable, but the system response is worse; the filter time is set too short, the system response is fast, but the control is unstable. So it should be based on the actual scene to make adjustments.
  2. To set the corresponding manual, automatic switching operating function. Optional manual, automatic, forced manual functions of manual operator. If necessary, could also consider the redundant operation function of the current and voltage setting, that is, the VFD frequency setting signal use current setting in normal, using voltage setting in abnormal manual operation. That is, add a potentiometer for setting g the VFD frequency, so the VFD frequency reference signal has two types, current signal and voltage signal. Because there are two types of frequency setting signals input in the VFD, increasing its redundancy degree.
  3. Must set the "overhaul switch", that is, set the "on-site overhaul switch" next to the operating equipment, when switch it to the "overhaul" position, equal to cut off the VFD running signal circuit. If someone misuse, the equipment can't run, to ensure that the safety of mechanical equipment maintainer.
  4. Make full use of the VFD input and output control terminals function, to carry out some alarm and interlock function, to reduce wiring and improve reliability.
  5. For single or simple control system, can take full advantage of the VFD built-in PID control function to reduce the control system equipments and reduce investment.
  6. Some VFD have input terminals R0, T0 of control power. So should connect control power to VFD R0, T0 side in front of the main power supply. So that the VFD still has a display function after the trip, in order to analyze the cause of the malfunction and take countermeasures.