Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
Digital Stepper Motor Driver, 3 Phase, AC 180V ~ 230V
 
Close
Shopping Categories
Search

Digital Stepper Motor Driver, 3 Phase, AC 180V ~ 230V


$264.29
Digital stepper motor driver works at AC 180V ~ 230V power supply, adjustable drive current 1.3A ~ 7.0A, impulse response fre
SKU: CHN-STEP-M2207T
Free Shipping Worldwide
Delivery date: 6-12 days

ATO digital stepper motor driver is an ideal choice for Nema 42, 51 bipolar stepper motor solution. This stepper motor controller can realize precise position control even without a feedback system.

Features

  • Digital stepper motor driver is high performance, extra-low noise and good stability.
  • Unique control circuit, high speed response.
  • When the step pulse stops over 100ms, the coil current automatically halved.
  • Over current, over voltage, under voltage, short circuit protection.
  • Suitable for 3 phase Nema 42, Nema 51 hybrid bipolar stepper motors.

Specification

ModelCHN-FYTM2207T
Matched MotorNema 42, 51 3 Phase Stepper Motor
VoltageAC 180V ~ 230V
Drive Current1.3A ~ 7.0A 16 Channels
Microstepping Setting60000 steps/rev 16 Channels
Hightest Pulse Frequency200Kpps
CertificationCE, FCC, RoHS
Dimensions202 x 147 x 78mm
Weight1.5kg
Function Description
FunctionsOperation Instructions
PUL+Positive End of Control Pulse SignalConnect to +5V power supply, +5V ~ +24V can be driven, higher than +5V need to connect current limiting resistor.
PUL-SW9=OFF, PUL is the pulse control signalThe falling edge is valid, and the motor takes one step whenever the pulse changes from high to low. Input resistance 220Ω. Requirements: low level 0 to 0.5V, high level 4 to 5V, pulse charge >2.5us.
SW9=ON, PUL is a positive pulse signal
DIR+Positive End of Directional SignalConnect to +5V power supply, +5V ~ +24V can be driven, higher than +5V need to connect current limiting resistor.
DIR-SW9=OFF, DIR is the direction control signalUsed to change the direction of the motor. Input resistance 220Ω. Requirements: low level 0 to 0.5V, high level 4 to 5V, pulse charge >2.5us.
SW9=ON, DIR is the reverse pulse signal
ENA+Positive End of Enabling SignalConnect to +5V power supply, +5V ~ +24V can be driven, higher than +5V need to connect current limiting resistor.
ENA-Negative End of Enabling SignalWhen it is valid (low level), the motor coil current is turned off, the driver stops working, and the motor is in a free state.
ALM+Positive End of Alarm Signal OutputWhen over-current, over-voltage, under-voltage or over-tolerance alarms, the alarm signal is valid (the output photocoupler is turned on). ALM+ is connected to the pull-up power to use the positive pole of the output power supply, and ALM- is connected to the negative pole of the output power supply. Maximum drive current 50mA.
ALM-Negative End of Alarm Signal Output
RDY+Positve End of Ready to Signal outputThe driver is in a normal state and is active when the controller signal is ready to accept (low level).
RDY-Negative End of Ready to Signal output
24PUL+Positive End of Signal Input+24V can be driven.
24DIR+Positive End of Signal Input+24V can be driven.
24ENA+Positive End of Signal Input+24V can be driven.

Operating Current Setting

Peak CurrentSW1SW2SW3SW4
1.3Aoffoffoffoff
1.6Aoffoffoffon
2.1Aoffoffonoff
2.3Aoffoffonon
2.5Aoffonoffoff
3.0Aoffonoffon
3.2Aoffononoff
3.5Aoffononon
4.0Aonoffoffoff
4.5Aonoffoffon
5.0Aonoffonoff
5.3Aonoffonon
5.8Aononoffoff
6.2Aononoffon
6.5Aonononoff
7.0Aonononon

Microstep Segmentation Setting

Pulse/RevoSW5SW6SW7SW8
400onononon
500onononoff
600ononoffon
800ononoffoff
1000onoffonon
1200onoffonoff
2000onoffoffon
3000onoffoffoff
4000offononon
5000offononoff
6000offonoffon
10000offonoffoff
8000offoffonon
20000offoffonoff
30000offoffoffon
60000offoffoffoff

Dimensions (Unit: mm)

Dimensions of 3 Phase AC 180V-230V Digital Stepper Motor Driver

Wiring Diagram

Wiring Diagram of-3 Phase AC 180V-230V Digital Stepper Motor Driver

Tips: Precautions for grounding of stepper motor driver

  • If there is no isolation between the AC power supply and the DC bus of the drive, do not connect the non-isolated port of the DC bus or the ground of the non-isolated signal to the earth, which may cause equipment damage and personal injury. Because the AC public voltage is not to the ground, there may be a very high voltage between the DC bus ground and the ground.
  • In most stepper systems, all common ground and ground are connected together at the signal end. The ground loops generated by multiple ways of connecting the ground are easily affected by noise and generate flow at different reference points.
  • In order to keep the command reference voltage constant, the stepper motor must connect the signal ground of the stepper motor driver to the signal ground of the controller.