Fixed Ozone (O3) Gas Detector, 0 to 1/5/10/20/50/100 ppm


$849.97
Reliable manufacturer Ozone gas detector for sale. Available measuring range 0-1/5/10/20/50/100 ppm, sound and light alarm by
SKU: CHN-GAS-O3-A
Free Shipping Worldwide
Delivery date: 6-12 days

Buy low price gas detector for Ozone detecting and monitoring. Measuring range 0-1/5/10/20/50/100 ppm, optional output signal 4-20mA/ RS485. O3 gas detector has sound and light alarm, remote control, real time display and 24 hours operating. Fixed installation, convenient use, easy calibration.

Features

  • Ozone gas detector adopts high precision sensor for accurate gas leak detection.
  • Ozone gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The O3 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The Ozone gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The O3 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelCHN-GAS-O3-A
Detection PrincipleElectrochemistry
GasOzone (O3)
Range (Optional)0-1 ppm
0-5 ppm
0-10 ppm
0-20 ppm
0-50 ppm
0-100 ppm
Resolution0.001 ppm, 0.01 ppm, 0.1 ppm (related to the selected range)
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional) Note4-20mA, or RS485 (transfer card included);
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionG1/2 male thread explosion-proof flexible pipe
Operating Time24h
Explosion-proof GradeEx d llC T6
Protection GradeIP65
CertificationCE, ATEX
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
AccessoriesPower adapter: Input 100-240VAC 50/60Hz, Output 24VDC 2A (Optional USA plug & Europe plug)

Note: The output signal 4-20mA and RS485 CANNOT be used at the same time.

Fixed Ozone (O3) Gas Detector Dimension (Unit: mm)

Fixed gas detector with alarm dimension

***Other Common Gases and Ranges Available for Fixed Gas Detectors

GasRange (Default)Range (Optional)Resolution
Combustible Gas (EX)0-100% LEL0-100% LEL1%LEL
Oxygen (O2)0-30% Vol0-25% Vol0.01%Vol
Carbon Monoxide (CO)0-1000 ppm0-100/500/1000/2000 ppm0.01ppm/0.1ppm/1ppm
Hydrogen Sulfide (H2S)0-100 ppm0-50/100/500/1000 ppm0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL0-100% LEL1%LEL
Chlorine (Cl2)0-10 ppm0-10/20/50/100 ppm0.01ppm/0.1ppm
Hydrogen Chloride (HCL)0-20 ppm0-10/20/50/100 ppm0.01ppm
Hydrogen (H2)0-1000 ppm0-1000/2000/5000/10000 ppm0.1ppm/1ppm
Nitric Oxide (NO)0-100 ppm0-100/250/500/1000 ppm0.01ppm/0.1ppm/1ppm
Nitrogen Dioxide (NO2)0-20 ppm0-20/50/100 ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10 ppm0-10/20/-50/100 ppm0.01ppm/0.1ppm/1ppm
Ozone (O3)0-10 ppm0-1/5/10/20/50/100 ppm0.001ppm/0.01ppm/0.1ppm
Carbon Dioxide (CO2)0-2000 ppm0-1000/2000/5000/10000/50000 ppm0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20 ppm0-10/20/100 ppm0.01ppm/0.1ppm
Ethylene Oxide (ETO)0-100 ppm0-20/50/100/500/1000 ppm0.01ppm/0.1ppm/1ppm
Phosphine (PH3)0-10 ppm0-10/20/50/100/200/500/1000 ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-100% Vol0-100% Vol0.01%Vol
Hydrogen Fluoride (HF)0-10 ppm0-50 ppm0.01ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Tips: Common faults of ozone gas detector.

  • If the ozone gas detector cannot be turned on, it is because the voltage is too low. The solution method is to connect the power supply or charge in time.
  • Indication value of the ozone gas detector is inaccurate, which is caused by the long-term uncalibrated detector and the sensor overtime. The solution is to replace the sensor.
  • When there is no O3 gas, interface of the ozone gas detector displays a value, which is caused by the drift of sensor, so the zero point calibration should be carried out in time.
  • If the normal detection interface of the ozone gas detector displays full scale, it is caused by a sensor failure. Replace the sensor in time
  • If the sensor of O3 gas detector drifts too much and the zero point calibration function is not available, the sensor should be calibrated or replaced in time.
  • Ozone gas detector does not respond to the detected O3. The possible cause is a circuit failure or the end of the life of the sensor. The treatment method is timely maintenance.