Digital clamp meter has AC current range 0-600A, TRMS/NCV/temperature/capacitance functions, maximum jaw opening size 28mm, 4 digit display and maximum value 1999.
Specification:
Basics | Model | CHN-UA3268B |
Weight | 160g |
Size (L*W*H) | 185*51*25mm |
Display | 4 digit LCD display |
Maximum display value | 1999 |
Power supply | DC 3V, 2 AAA batteries |
Maximum jaw opening size | 28mm |
Woring environment | Temperature: 5℃~35℃ (41℉~95℉), relative humidity:<75% |
Storage temperature | -10℃~+50℃ (14℉~122℉) |
Accessories | A pair of test probes, a pair of temperature probes, a user manual, 2 AAA batteries |
Functions | Item | Range | Accuracy |
AC current | 600A | ±(1.5%+5 digits) |
DC voltage | 600V | ±(1.0%+5 digits) |
AC voltage | 600V | ±(1.2%+5 digits) |
Resistance | 20MΩ | ±(1.0%+2 digits) |
Frequency | 100kHz | ±(1.5%+5 digits) |
Capacitance | 100mF | ±(4.0%+3 digits) |
Temperature | -40℃~+1000℃ (-40℉~1832℉) | ±(1.0%+3 digits) |
Special functions | TRMS | True RMS measurement for sine wave signal |
NCV | Non-contact voltage test |
Diode test | Display forward voltage value of diode |
On-off buzzer | Continuity test buzzer |
Data hold | Hold the reading when taking a measurement |
Automatic power off | Automatic power off when 15 minutes no operation |
Overload protection | Overload protection for 100% range |
Range selection | Automatic range selection and manual range selection |
Backlight | Backlight for LCD display |
Inspection light | Inspection light for clamp operation |
Tips: Clamp meter NCV function, the Non-Contact voltage measurement
Set the function range switch to the NCV position. At this time, the digital clamp meter displays 'NCV' and '----'symbols, and the top of the clamp meter is close to the object to be detected such as the mains phase line, the power switch and the outlet. When the voltage is detected to be greater than 110V (AC RMS), the meter lights up the corresponding signal strength indicator (high, medium and low) according to the detected signal strength, and the buzzer will give out alarm at different frequencies.
Note:
- Even if there is no indication, the voltage may still exist. Do not rely on non-contact voltage detectors to determine if there is voltage on the shield. Detection operations may be affected by socket design, insulation thickness and type of different factors.
- When the input voltage of the instrument input terminal, due to the existence of induced voltage, the voltage sensing indicator may also be bright.
- Sources of external environment interference (such as flash, motor, etc.) may falsely trigger non-contact voltage detection.
The mini clamp meter is a digital clamp multimeter can be used to measuring AC current 0-600A, AC/DC voltage 0-600V, resistance 0-20MΩ, frequency 0-100kHz, capacitance 0-100mF and temperature -40℃~+1000℃ (-40℉~1832℉). Digital mini clamp meter has special functions of NCV and TRMS. The maximum jaw opening size is 28mm.