Digital clamp meter has AC/DC current range 0-100A, TRMS/NCV/temperature/capacitance functions, maximum jaw opening size 22mm, 4 digit display and maximum value 1999.
Specification:
Basics | Model | CHN-UA220D |
Weight | 144g |
Size (L*W*H) | 175*55*32mm |
Display | 4 digit LCD display |
Maximum display value | 1999 |
Power supply | DC 3V, 2 AAA batteries |
Maximum jaw opening size | 22mm |
Woring environment | Temperature: 5℃~35℃ (41℉~95℉), relative humidity:<75% |
Storage temperature | -10℃~+50℃ (14℉~122℉) |
Accessories | A pair of test probes, a pair of temperature probes, a user manual, 2 AAA batteries |
Functions | Item | Range | Accuracy |
DC current | 100A | ±(2.5%+10 digits) |
AC current | 100A | ±(2.5%+8 digits) |
DC voltage | 500V | ±(1.0%+5 digits) |
AC voltage | 500V | ±(1.5%+5 digits) |
Resistance | 20MΩ | ±(1.2%+3 digits) |
Frequency | 100kHz | ±(0.3%+5 digits) |
Capacitance | 100mF | ±(5.0%+3 digits) |
Temperature | -50℃~+1000℃ (-58℉~1832℉) | ±(1.9%+6 digits) |
Duty ratio | 0.1%~99.9% | ±(0.5%+3 digits) |
Special functions | TRMS | True RMS measurement for sine wave signal |
NCV | Non-contact voltage test |
Diode test | Display forward voltage value of diode |
On-off buzzer | Continuity test buzzer |
Data hold | Hold the reading when taking a measurement |
Automatic power off | Automatic power off when 15 minutes no operation |
Overload protection | Overload protection for 100% range |
Range selection | Automatic range selection and manual range selection |
Backlight | Backlight for LCD display |
Inspection light | Inspection light for clamp operation |
Tips:
The mini digital clamp meter is a AC/DC clamp multimeter with TRMS/NCV/temperature/capacitance functions. It can be used to measuring AC/DC current 0-100A, AC/DC voltage 0-600V, resistance 0-20MΩ, frequency 0-100kHz, capacitance 0-100mF and temperature -50℃~+1000℃ (-58℉~1832℉). The maximum jaw opening size is 22mm.