Three phase centrifugal pump with 2900rpm motor speed, 0°, 90° and 180° installation angle of outlet and same diameter of inlet and outlet 40mm (1~1/ 2 inch). 3 phase centrifugal water pump has advantages of simple structure, low noise and long service lifetime.
Features:
- The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
- It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
- Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
- The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.
Specification
- Model: CHN-HCP-40-250I
- Power: 15 hp (11 kW)
- Number of stages: Single stage
- Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
- Input frequency: 50Hz/ 60Hz
- Inlet diameter: 40mm (1-1/2 inch)
- Outlet diameter: 40mm (1-1/2 inch)
- Flow (min. flow to max. flow): 8.8 m³/ h (38.7gpm), 12.5 m³/ h (55gpm), 16.3 m³/ h (71.8gpm)
- Head (max. head to min. head): 81.2m (266ft), 80m (262ft), 77.5m (254ft)
- Efficiency: 31%/ 38%/ 40%
- Nominal diameter of impeller: 250mm
- Size: 500*790*340mm
- Weight: 180kg
Dimension (mm)
Boundary dimension | h | H | L | a | A |
280 | 500 | 790 | 100 | 65 |
Base dimension | L1 | B | I | b | h1 | 4-φd1 |
560 | 340 | 510 | 240 | 100 | 4-φ18 |
Flange dimension | D | D1 | n-φd |
φ150 | φ110 | 4-φ18 |

Tips: Centrifugal Pump Troubleshooting - Motor Current is too High.
- Reason 1: The power of the supporting motor is too small. The solution: adjust the supporting motor and replace the motor.
- Reason 2: The revolving speed of the water pump is too high. The solution: reduce the revolving speed of the water pump.
- Reason 3: The pump shaft is bent and the bearing is worn or damaged. The solution: correct the straightening of the pump shaft, repair or replace the bearing.
- Reason 4: The stuffing is compressed too tight. The solution: release the stuffing gland.
- Reason 5: In practical operation, the head is much lower than the pump head, causing a too high flow rate. The solution: turn down the outlet valve and control the water pump flow rate.
- Reason 6: The coupling is not concentric, or the clearance between the couplings is too small. The solution: correct the concentricity or adjust the clearance between the couplings.
- Reason 7: The pump has been stopped for a too long period, thus causing heat expansion. The solution: implement the normal operation procedure, stop immediately for inspection in case of a fault.
- Reason 8: The motor is wetted because of being dipped in water. The solution: dry the wet motor.
Horizontal centrifugal pump with 15 hp motor power, optional input voltage 3 phase AC 220V to 480V and input frequency 50Hz/ 60Hz for selection. Single stage centrifugal pump with maximum flow 16.3 m³/h (71.8 gpm), maximum head 81.2m (266ft). Centrifugal water pump can be used for high-rise building pressurized water supply, HVAC & refrigeration water circulation.