3.7 kW AC line reactor for VFD, 10A rated current, 3 phase input, 50Hz/60Hz operating frequency. This is a high performance and high reliability input reactor with multiple choices, not only full set accessories but also low price.
5 hp Input Line Reactor Specifications
Basic | Model | ATOACR-0010-1M40-0.4SC |
Recommended VFD Model | GK3000-4T0037G (5 hp three phase VFD) |
Phase | 3 Phase |
Power | 5 hp (3.7 kW) |
Weight | 2.8 kg |
Technical Parameters | Work Valtage | 380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V) |
Work Frequency | 50Hz/60 Hz |
Rated Current | 10 A |
Max Current | 1.5 Times the Rated Current, Continued 60s |
Inductance Value | 1.4 mH |
Material | Aluminium/Copper (Optional) |
Voltage Drop | 2% |
Noise | ≤65dB |
Insulation Class | Class F, H |
Protection Class | IP00-IP22 |
Insulation Resistor | ≥100MΩ |
Working Environment | Operation Environment | -10℃~+45℃ |
Temperature Rise | ≤85K |
Humidity | ≤90%RH, without condensation |
Running Ambient Temperature | -25℃~+45℃ |
Altittude | ≤2000m |
5 hp Input Line Reactor Size & Circuit Diagram


Dimension (±5mm) |
L | D | W | W1 | H | A×B |
115mm | 90mm | 95mm | 68mm | 135mm | 6×11 |
Tips: What about burnout of line reactor?
If the concrete column of AC input line reactor and porcelain support insulator crack or some coils of electric reactor burn out, check whether relay protection functions. If relay protection doesn’t function, disconnect the power supply of input line reactor manually, stop faulted input line reactor and start the standby input line reactor.
Low price 5 hp AC line reactor for sale, with 10A current, 3 phase input, voltage 380V, 400V, 440V, 460V and 480V for selection, vfd line reactor direct sales by manufacturer, small size and light weight.