Compact-size electromagnetic relay is used for general purpose with 11 pins, 3PDT contct type, and widely applied in electronic equipment, communication equipment, automatic control system, instrument and meters, etc.
Specification
Basics | Model | CHN-JZX-22F(D)/3Z (Relay with Socket) |
Dimension (L*W*H) | 27.5×31×35mm |
Weight | 50g |
Ambient Temperature | -25℃~+55℃ |
Terminal Type | Plug in |
Number of Pins | 11 |
Technical Parameters | Contact Form | 3PDT |
Contact Material | Silver alloy |
Contact Capacity (Resistive load) | 10A/240V AC 28V DC |
Coil Power | DC≤0.9W, AC≤1.2VA |
Coil Voltage | Optional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC |
Pick-up Voltage at 23℃ | DC≤75%, AC≤80% |
Drop-out Voltage at 23℃ | DC≥10%, AC≥30% |
Contact Resistance @6V DC 1A | ≤100MΩ |
Dielectric Strength | Between open contact | ≥1200V AC 50Hz/1min |
Between adjacent contact | ≥1500V AC 50Hz/1min |
Between coil & contact | ≥1500VAC 50Hz/1min |
Leakage current | ≤1mA |
Insulation Resistance (MΩ) | ≥500MΩ at 500V DC |
Service life | Electrical | 105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s) |
Mechanical | 106 Times (Frequency: 300 Time/1min) |
Note: Here just shows the contact form 3PDT, and another contact forms 3NO and 3NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.
Dimensions & Connection Diagram

Tips: How to select a relay?
- Working environment
Working environment mainly refers to temperature (maximum and minimum temperature), humidity (maximum relative humidity in -40℃), low pressure (it is unnecessary for places with an elevation of lower than 1,000 meters to consider the factor), oscillation and impact. In addition, service environment involves requirements for packaging mode, installation mode, shape, dimensions, and insulation performance etc. - Input signals
Select electromagnetic, temperature, time or photoelectric relays by judging whether input signals are electricity, temperature, time or photo signals. - Input parameters
Input parameters refer to working voltage (or current) of the coil. Pull-in voltage (or current) refers to the parameter used by relay producers to control sensitivity of relays. - Load conditions
Configurations and groups of contacts shall be determined according to actual conditions of controlled circuit. It is very important to determine parameters according to load capacity and load nature (resistive, inductive, capacitive, light load and motor load).
Low cost and high quality electromagnetic relay, 11-pin 3PDT, plug-in terminals, silver alloy contacts, and contact load 10A/240V AC 28V DC, common coil voltages of 12VDC / 24VDC / 110VAC / 220V AC for your choice.