Electromagnetic Relay, 8-pin DPDT, 12V/24V/110V/220V coil


$53.69
Electromagnetic relay with plug-in terminals, 8 pins DPDT, silver alloy contacts, optional coil volatge 12V DC, 24V DC, 110V
SKU: CHN-EMR-MK2P1
Free Shipping Worldwide
Delivery date: 6-12 days

8-pin electromagnetic relay with DPDT contact configuration can be widely used in remote control, electronic equipment, communication equipment, automatic control system and tools etc. Low cost and high quality.

Specification

BasicsModelCHN-MK2P-1 (Relay with Socket)
Dimension (L*W*H)35×35×53mm
Weight76g
Ambient Temperature-25℃~+55℃
Terminal TypePlug in
Number of Pins8
Technical ParametersContact FormDPDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)10A/250V AC 28V DC
Coil PowerDC≤2W, AC≤3.5VA
Coil VoltageOptional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1200V AC 50Hz/1min
Between adjacent contact≥1500V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
MK2P electromangetic relay dimensions connection diagramRelay Socket Size
MK2P 1 electromagnetic relay socket size

Tips: Applications of electromagnetic relays

  1. Flood alarm: open or close a circuit by changes of water level to realize alarm function.
    When the water level exceeds the warning line, the floater will float up. As a result, the circuit will be closed and the electromagnet will attract the armature. Then, alarm indicator is powered on to alarm users.
  2. Automatic temperature alarm: the level of mercury changes with temperature. Its changes could be used to control opening and closing of the circuit and realize function of the automatic temperature alarm. When temperature rises to a threshold value, mercury in the thermometer will rise to the wire. Mercury is a kind of conductor, so it could be used to close the circuit of the electromagnetic system. As a result, the electromagnet will attract the spring and close the alarm circuit to make it ring up. When temperature falls, mercury in the thermometer will be disconnected from the wire. Consequently, the spring will restore its position and the electromagnetic circuit will be opened to silence the alarm.