Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
CCHN Industry
 
Close
Shopping Categories
Search

CCHN Industry

CCHN is a trusted U.S. registered company in industrial automation & controls, CCHN's goal is helping saving your money by bypassing all kinds of local dealers/agents in buying industrial automation products from Chinese manufacturers directly. You will be enjoyed to get free tech support on how to choose, how to wire, how to commissioning with CCHN professional engineers. Shopping for your automation systems on CCHN one-stop online store now. The price on the website only for sample reference. for Mass order,please send the enquiry to us.

Blog

Foam cutting is a device for processing materials in the chemical industry such as foam and sponges. It mainly uses the high

...
12AWG Hook-Up Wire, UL1015, 600V, 1000 ft
 
Close
Shopping Categories
Search

12AWG Hook-Up Wire, UL1015, 600V, 1000 ft


$509.19
Hook-up wire for sale, 12AWG, 600V rated voltage, UL1015 standard, 1000 ft., PVC outer cover for insulation, optional differe
SKU: CHN-UL1015-12
Free Shipping Worldwide
Delivery date: 6-12 days

Hook up wire provides good electrical connection and PVC insulation keeps wires from abrasion, chemical and solvents. The insulated wire is widely used for industrial, electronics and automotive applications.

Specification

ModelCHN-UL1015-12
UL Style1015
Size12 AWG
Rated Voltage600V
Color (Optional)White, Black, Red, Yellow, Green, Brown, Gray, Blue, Orange, Purple
Rated Temperature105 ℃
ConductorTinned/ Bare Copper
Conductor TypeStranded
Conductor Size (±0.005)NO. 65/ 0.254mm
Conductor Resistance 20℃5.64.00 Ω/km
Conductor Diameter2.36mm
InsulationPVC
Insulation ThicknessNom.0.80mm
Min.0.69mm
Overall DiameterAverage3.96mm
Tolerance±0.15mm
Package1000 ft/roll
Weight13kg

Details

Details of UL1015 10AWG Isulated Copper Wire

Tips: What are the reasons for the heating of UL hook up wire in operation?

When the electric wire and cable exceed a certain load current, they must heat up. With the increase of the load current, the higher the surface temperature of the wire, if not handled in time, the consequences can be imagined. For example, the PVC wire, the core temperature is 70℃ as the upper limit of consideration, the surface temperature will be 5~10℃ lower. So the surface temperature of the wire below 60℃ is basically safe. From the power supply maintenance consideration, the lower the temperature, the better.

Electrical wire get hot during operation for the following reasons:

  • Wire conductor resistance does not meet the requirements, resulting in the heat in the operation of the wire.
  • Improper choice of UL hook up wire resulting in the use of wire conductor cross section is too small and overload occurs in operation. After a long time of use, the imbalance of heat dissipation of the wire causes the phenomenon of heat.
  • The UL wire installation arrangement is too dense. Ventilation and heat dissipation effect is not good or the wire is too close to other heat sources,
    affecting the normal heat dissipation of the wire and causing the wire in the operation of the heat phenomenon.
  • Wire phase insulation performance is not good, resulting in small insulation resistance and producing heat phenomenon.

After the power wire generates heat, if it the faults are not found and removed in time, the insulation thermal breakdown will occur after the wire is to be powered on continuously. This will cause the electrical wire alternating short circuit even the fire.